1. Disconnect the compressor power cord from outdoor PCB (refer to "DISASSEMBLY INSTRUCTIONS" on page 39).
2. Measure the resistance value of each winding using a multi-meter.
3. Check the resistance value of each winding in the Tables 8 - 10.
RESISTANCE VALUE
Blue-Red
Blue-Black
Red-Black
RESISTANCE VALUE
Blue-Red
Blue-Black
Red-Black
RESISTANCE VALUE
Blue-Red
Blue-Black
Red-Black
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Table 8 — Resistance Value
KSN98D64UFZ3
KSN140D21UFZ
2.7
Table 9 — Resistance Value
KTF250D22UMT
KSN140D58UFZ
ATF235D22TMT
0.75
Table 10 — Resistance Value
ATM150D23TFZ
ATH307CDRC8DUL
1.72
NOTE: The image and the value are for reference only.
KTM240D43UKT
1.28
1.03
KTF310D43UMT
ATF310D43TMT
1.86
0.65
KSK103D33UEZ3
1.09
2.13
36
KTM240D57UMT
0.62
KTQ420D1UMU
ATQ420D1SN5A1
0.37
KTN110D42UFZ
1.82