Case Front Controls - Lincoln Electric DLF-82 Operator's Manual

Table of Contents

Advertisement

DLF-82
®

CASE FRONT CONTROLS

3
1
6
7
2
11
10
Wire Feed Speed Digital Display - The DLF-82 has a digital
display that shows the wire feed speed. This display is also
capable of displaying amperage and the setup menu.
Wire Feed Speed Knob - Use the Wire Feed Speed Knob to set
the rate of wire feed speed. The wire feed speed will be
displayed on the Wire Feed Speed Digital Display. During CV
operation, the wire feed speed will remain a constant value,
independent of arc voltage changes.
4
8
9
15
14
5
13
12
3. Voltage/Trim Digital Display - The DLF-82 has a digital
display that shows the voltage/trim between electrode and
work.
4. Voltage
Knob - Use the Voltage Knob to set the voltage
and it will be displayed on the Voltage Digital Display. During
CV operation, the voltage will remain stable while welding.
5. Alphanumeric Display - Shows wire type, wire size, process
name, gas type, active procedure and active memory. This
display is also capable of displaying settings menu parameters.
Wire Feed Speed LED - The Wire Feed Speed and Amperage
LEDs will communicate what is being displayed on the Wire
Feed Speed Digital Display. When the Wire Feed Speed LED is
illuminated, wire feed speed is being displayed.
7.
Amperage LED - When the Amperage LED is illuminated,
amperage is being displayed.
8.
Voltage LED - The Voltage LED will be illuminated when the
Voltage Digital Display is displaying actual voltage.
9.
Trim LED - When the Trim LED is illuminated, a Trim value is
being displayed.
10.
Five Pin Gun Trigger Connector - The 5 Pin Gun Trigger
Connector is where the trigger that is attached to the welding
gun is connected. This will actuate the welding current when
the trigger is pulled.
Menu Selection and Adjustment - Push for a half second to enter
11.
the menu screens, turn knob to display the memory options. Push
Memory Button - Push to select between 4 memory locations.
12.
Push and hold to save the active weld schedule. The memory
button also serves as an exit button while in the menu screen.
13.
Cold Inch Button - Push to activate wire drive motor without
energizing the feedplate and release to halt feeding.
14.
Gas Purge Button/4 Step Button
to close the gas solenoid, allowing shielding gas to ow and release
to open the solenoid. While the button is pushed, and for 3 seconds
after releasing it, the upper right knob can be used to turn 4 step on
or off. To get the "4stp" "On"/"Off" menu to turn off faster than the
3 second timer, just press either the gas purge or the back button
once to exit.
15. 4 Step LED - The 4 step LED will be illuminated when 4 step is
enabled.
B-13
OPERATION
- Push and hold for 0.5 second

Advertisement

Table of Contents
loading

This manual is also suitable for:

132401324113242

Table of Contents