BURNERS
Auxiliary (A)
Semi-rapid (SR)
Rapid (R)
Double-ring compact (MW)
Double-ring (DCS)
AIR VENT NECESSARY FOR GAS COMBUSTION = (2 m
BURNERS
Auxiliary (A)
Semi-rapid (SR)
Rapid (R)
Double-ring compact (MW)
Double-ring (DCS)
LUBRICATION OF THE GAS TAPS
In case of difficulty in the gas taps operation, call Service.
IMPORTANT
All intervention regarding installation, maintenance and conversion of the appliance
must be fulfilled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.
16
16
GAS MAINTENANCE
TABLE FOR THE CHOICE OF THE INJECTORS
Nominal Power
[g/h]
73
122
219
255
255
Reduced Power
[kW]
[g/h]
1,00
25
1,68
36
3,00
73
3,50
109
3,50
116
Air necessary for combustion [m
LPG (PROPANE/
BUTANE) 5 kPa
Ø injector
[kW]
[1/100 mm]
0,34
46
0,50
58
1,00
79
1,50
85
1,60
84
/h x kW)
3
/h]
3
2,00
3,36
6,00
7,00
7,00