Parameter (Continued)
Radio
Frequency
Range
Environmental
Temperature Ranges:
Operating
Charging
Storage with battery*
Storage without battery
Humidity
Mechanical Drop
ESD Sensitivity
Image
Image Size
Scan Performance
Skew Angle
Pitch Angle
Motion Tolerance
Symbol Contrast
Field of View
XP SR
XP XR
*Storage outside of this temperature range could be detrimental to battery life.
Granit XP User Guide
Expected Charge Time
1D barcode
2D barcode
Specification
4.5 hours + 0.5 hours
2.4 to 2.5 GHz (ISM Band) Frequency Hopping
Bluetooth v 4.2
33 ft. (10 m) typical
-4°F to +122°F (-20°C to 50°C)
32°F to 113°F (0°C to 45°C)
-4°F to +95°F (-20°C to 35°C) for storage up to 90
days
-4°F to +68°F (-20°C to 20°C) for storage up to 365
days
-40°F to +158°F (-40°C to 70°C)
Up to 95% non-condensing
2 m (6.5 ft): 50 drops from -30°C to 50°C (-22°F to
122°F), uncontrolled RH
2.4 m (8 ft): 20 drops at 25°C (77°F), 55% RH
3 m (10 ft): MIL-STD-810G, 25°C (77°F), 55% RH
Up to ±20kV direct air
Up to ±8 kV indirect coupling
1280 x 800 pixels
+65°
1D barcodes: +65°
2D barcodes: +45°
Up to 4.5 m/s (157 in/s) for 13 mil UPC at optimal
focus
20% or greater (Grade A)
48°H 30°V
Near 48°H 30°V
Far 19°H 11.9°V