INTRODUCTION
Your LYNX Temperature Control System can supply a complete network of temperature control by providing each system with an Operator Interface
Panel and PID Control Modules for each heater. A LYNX Module is a compact controller that fits on to a LYNX Docking Station. The Docking Station
has wires that control power to the heater as well as a temperature sensor such as Type-J or Type-K thermocouples as well as PT100-RTD sensors.
This Quick Start manual is a simple guide for commissioning LYNX System hardware. If using without an Operator Interface, disregard those refer-
ences. For more detailed information, including commissioning with an Operator Interface and Modbus Registers, refer to LYNX Full Instruction Man-
ual 41295-10. Safety and Warning information is contained in manual 41295-09.
NOTE: READ ALL INSTRUCTION INFORMATION BEFORE ASSEMBLY, INSTALLATION, AND STARTUP.
®
© BriskHeat
TM
LYNX
System Instructions
.
Corporation. All rights reserved
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LYNX and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BriskHeat LYNX

  • Page 1 Your LYNX Temperature Control System can supply a complete network of temperature control by providing each system with an Operator Interface Panel and PID Control Modules for each heater. A LYNX Module is a compact controller that fits on to a LYNX Docking Station. The Docking Station has wires that control power to the heater as well as a temperature sensor such as Type-J or Type-K thermocouples as well as PT100-RTD sensors.
  • Page 2: General Specifications

    LYNX System Instructions LYNX System Instructions GENERAL SPECIFICATIONS GENERAL SPECIFICATIONS • • Especificaciones Generales Allgemeine Anforderungen • • Specifiche Generali 一般仕様 • • Especificaciones Generales Allgemeine Anforderungen • • Spécifications Générales 一般规格 • • Specifiche Generali 一般仕様 • • Spécifications Générales 一般规格...
  • Page 3 LYNX System Instructions LYNX System Instructions OPERATOR INTERFACE BEDIENERSCHNITTSTELLE Ethernet Port Ethernet-Port Module Communication Connector Steuerungsmodulanschluss Dry Contact Relays Trockenkontaktrelais DOCKING STATION ASSEMBLY DOCKING-STATION-ZUSAMMENBAU USB Port USB-Port Power / Communication Input Stromzufuhr- / Kommunikationseingang INTERFACCIA OPERATORE INTERFACE DE L'OPÉRATEUR Heater Power Output Heizgerätleistungsausgang...
  • Page 4: Installation Instructions

    LYNX モジュール Botón de arriba [上] ボタン Botón de abajo • [下] ボタン Connect Lynx Module to Dock, ensure clips are fully engaged on both sides. Botón de función [ファンクション] ボタン • Lynx-Modul an Dock anschließen, sicherstellen, Luz indicadora LED LED 表示灯...
  • Page 5 功能 默认值 • Collegare tra loro gli eventuali Dock Lynx aggiuntivi. Collegare le prese del sensore e del riscaldatore per i dock indipendenti. Collegare un ca- blaggio di alimentazione al primo Dock in ogni stringa. Temperature Setpoint (Degrees) Temperatur-Sollwert (Grad) •...
  • Page 6 LYNX System Instructions LYNX System Instructions Module Color Indications Module Menu Parameters High Alarm Temperature (Degrees) Module Color Indications Modulfarbanzeigen Hochtemperaturalarm (Grad) Color (Action) Status Farbe (Aktion) Status Temperatura allarme Alta (gradi) Green (solid) Normal Operation Grün (dauernd an) Normalbetrieb Température d'alarme de niveau élevé...
  • Page 7 LYNX System Instructions LYNX System Instructions • Plug in the power connector on the back of the Operator Interface. Plug the Operator Inter- face power supply and the power harness into supply power to turn on the system. • Connect the first Dock of each string to the Operator Interface via the communication •...
  • Page 8: Operator Interface Panel

    LYNX System Instructions LYNX System Instructions OPERATOR INTERFACE PANEL Figure 6: OI Menu Screen Figure 5: OI Main Screen MENU SCREEN MENÜ-ANZEIGE Line Selection Panel Linienwahlanzeige MAIN SCREEN HAUPTANZEIGE Zone Selection Panel Zonenwahlanzeige Touch screen interface Touchscreen-Benutzerschnittstelle System Menu Systemmenü...
  • Page 9: Troubleshooting Guide

    INFORMACIÓN DE LA GARANTÍA BriskHeat ofrece al comprador original de este producto una garantía durante un periodo de dieciocho (18) meses a partir de la fecha de envío o doce (12) meses a partir de la fecha de la instalación, lo que ocurra primero. La obligación de BriskHeat y las soluciones exclusivas conforme a esta garantía se limitarán a la reparación y a la sustitución, a criterio de BriskHeat, de cualquier pieza del producto que se compruebe que sea...
  • Page 10 LYNX System Instructions LYNX System Instructions NOTE Europe: Corporate Headquarters: P.O. Box 420124 4800 Hilton Corporate Dr. 44275 Dortmund, Germany Columbus, OH 43232, U.S.A. Toll Free: 800-848-7673 Phone: 614-294-3376 Fax: 614-294-3807 Email: bhtsales1@briskheat.com ® ® © BriskHeat Corporation. All rights reserved ©...

Table of Contents