BriskHeat TC4000 Instruction Manual

Digital high capacity outdoor temperature controller

Advertisement

Quick Links

TC4000
Digital High Capacity
Outdoor Temperature
Controller
Instruction Manual
You must read and understand this manual before
installing, operating, or servicing this product. Failure to
understand these instructions could result in an
accident causing serious injury or death.
Keep these instructions for future reference.

TABLE OF CONTENTS

Introduction ........................................................................................................................... 2
Safety Alert Symbol .............................................................................................................. 2
Important Safety Instructions................................................................................................ 3
Specifications and Part Number Matrix ................................................................................ 4
Installation Instructions ......................................................................................................... 5
Power Input/Output Connections ........................................................................................ 6
Operation Overview .............................................................................................................. 9
Alarm Settings ................................................................................................................... 10
Glossary ........................................................................................................................... 11
Troubleshooting Guide ...................................................................................................... 12
Warranty Information ......................................................................................................... 13
INTRODUCTION
®
BriskHeat
TC4000 digital temperature
controllers are designed for general purpose
use in outdoor or indoor environments to
control temperatures on applications
requiring automatic control.
For additional information concerning this, or
®
other BriskHeat
products, please contact
®
your local BriskHeat
distributor or contact
us toll free (U.S. / Canada only) at
1-800-848-7673 or 614-294-3376.
Save these instructions for future use.
®
© BriskHeat
Corporation. All rights reserved.
TC4000 Digital High Capacity
Outdoor Temperature Controller
SAFETY ALERT SYMBOL
The symbol above is used to call your
attention to instructions concerning your
personal safety. It points out important
safety precautions. It means "ATTENTION!
Become Alert! Your Personal Safety is
involved!" Read the message that follows
and be alert to the possibility of personal
injury or death.
DANGER
Immediate hazards which WILL result in
severe personal injury or death.
WARNING
Hazards or unsafe practices that COULD
result in severe personal injury or death.
CAUTION
Hazards or unsafe practices that COULD
result in minor personal injury or property
damage.
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TC4000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BriskHeat TC4000

  • Page 1: Table Of Contents

    TC4000 Digital High Capacity Outdoor Temperature Controller TABLE OF CONTENTS Introduction ........................... 2 Safety Alert Symbol ......................2 Important Safety Instructions....................3 Specifications and Part Number Matrix ................4 Installation Instructions ......................5 Power Input/Output Connections ..................6 Operation Overview ......................9 Alarm Settings ........................
  • Page 2: Important Safety Instructions

                  Only qualified personnel are allowed to connect electrical wiring.  ® All electrical wiring must follow local electrical codes. BriskHeat highly recommends                               Ambient Temp ...
  • Page 3: Installation Instructions

    Enclosure Openings For maximum flexibility, TC4000 controllers are sold with no openings already made in the enclosure. Holes for conduit and fittings may be made using a standard hole saw. Take care to avoid damaging components when making holes. Be sure to clear debris completely.
  • Page 4 Use (▲▼) buttons to select the “r.P.” (Restricted Parameters) parameter keyword on the controller. The TC4000 controller can directly accept thermocouples with mini-connectors. Supported thermocou- ples are (J, K). The sensor type must be set in the controller. Be sure to observe correct polarity when Press the P button to select.
  • Page 5: Operation Overview

    NOTE: READ ALL INSTRUCTIONS PRIOR TO APPLYING POWER TO THE CONTROLLER Press and hold the P button for approximately 5 seconds. Use the UP and DOWN buttons to select the desired All TC4000 Controllers require temperature sensors, which may be Type-J, Type-K. Verify correct polarity of the parameter to change.
  • Page 6: Glossary

    Please read this guide prior to contacting BriskHeat . This guide is designed to answer the temperature. Note that the TC4000 only provides visual alarm capability, on the most commonly asked questions. If you are unable to identify the problem or need controller display.
  • Page 7: Warranty Information

    BriskHeat’s obligation and the exclusive remedy under this warranty shall be limited to the repair or replacement, at BriskHeat’s option, of any parts of the product which may prove defective under prescribed use and service following BriskHeat’s examination, is determined by BriskHeat to be defective.

Table of Contents