Westinghouse iGen11000DFc User Manual page 25

Digital inverter generator
Hide thumbs Also See for iGen11000DFc:
Table of Contents

Advertisement

MAINTENANCE
CLEANING/REPLACING THE AIR FILTER
See Figure 21.
Keep air filter clean. A dirty air filter can cause poor perfor-
mance and decrease the service life of the product. NEVER
operatethegeneratorwithoutanairfilterinplace.
l Turn the generator off and allow the engine to cool for
30 minutes.
l Turn the lock knob to the unlocked position and remove
the engine service cover.
l Release the tabs and remove the air filter cover.
l Remove the air filter from the air cleaner housing and
place it in a suitable cleaning container. Replace the air
filterifdamaged.
NOTE: The air filter may be covered in oil. Use an appro-
priate container.
l Wash the air filter by submerging the filter in a solution
of household detergent soap and warm water. Slowly
squeeze the filter to thoroughly clean.
NOTICE
DO NOT twist or tear the air filter during
cleaning or drying. Only apply slow but firm squeezing
action.
l Rinse the air filter by submerging it in fresh water and
applying a slow squeezing action. Allow the filter to dry
thoroughly.
NOTICE
Do not pollute. Follow the guidelines
of the EPA or other governmental agencies for proper
disposal of hazardous materials. Consult local author-
ities or reclamation facility.
l Dip the air filter in clean engine oil then squeeze out all
excess oil. The engine will smoke when started if too
much oil is left in the filter.
l Install the air filter in the air cleaner housing and reinstall
the air filter cover.
l Install the engine service cover and turn the lock knob to
the locked position to secure.
FIG. 21
B
A - Air filter cover
B - Air filter
C - Tab
D - Air filter box
CHANGING THE ENGINE OIL
See Figure 22.
For optimal performance, change the engine oil according
to the figures specified in the maintenance schedule or
the engine manual (if applicable). When using the generator
under extreme, dirty, dusty conditions or in extremely hot
weather, change the oil more frequently.
NOTE: Change the oil while the engine is warm but not
hot. Warm engine oil drains more quickly and thoroughly
than cool lubricant. Contact with hot lubricant will cause
serious burns.
l Turn the generator off and allow the engine to cool for
30 minutes.
l Place the generator on a level surface in a well-ventilated
area.
l Turn the lock knob to the unlocked position and remove
the engine service cover.
l Clean the area around the oil dipstick and drain bolt.
l Slowly unscrew and remove the oil dipstick.
D
C
A