User ER Pattern Bulk Data
Transmission is enabled on the MIDI channel of the currently selected bank. Data
is transmitted when BULK OUT 2 is displayed and BULK OUT is executed, and when
the USER ER PATTERN BULK DUMP REQUEST message is received. The data to be
transmitted is that of the indicated pattern number. If the pattern number is
" * " , patterns 1 - 4 ( A - D ) are transmitted in succession.
STATUS
11110000(F0H)
ID No.
01000011(43H)
SUB STATUS
0000nnnn(0nH)
FORMAT No.
01111110(7EH)
BYTE COUNT
00000001(01H)
BYTE COUNT
01101110(6EH)
01001100(4CH)"L"
01001101(4DH)"M"
00100000(20H)SPACE
00100000(20H)SPACE
00111000(38H)"8"
00110011(33H)"3"
00110111(37H)"7"
00111000(38H)"8"
DATA NAME
01000101(45H)"E"
ER PATTERN No.
Ozzzzzzz
DATA
0ddddddd
0ddddddd
CHECK SUM
Oeeeeeee
EOX
11110111(F7H)
n=0 (Channel No. 1)~15 (Channel N o . 16)
Z=ER PATTERN 1~4(1=A, 2=B, 3=C, 4=D)
228BYTE