Single Point Control Using One On-Off Toggle Switch
Sample 1
PowerCab Programming Set Up
13.5V
PowerCab
PSU
Set to
Accessory
Address 10
Power Pro Programming Set Up
18V Alpha Power PSU
If RE-SET light activates
turn main power switch
off to re-set protection
Fully Protected 18V 5A DCC Power Supply
NCE Power Pro Base Unit
POWERPRO
NCE Corporation
FROM
CONTROL BUS
POWER TRACK
16VAC / 28VDC MAX.
Accessory
Address 10
On-Off Toggle
Switch connected
to GND & Input 1
NCE PCP
Faceplate
6pin RJ12 Cable
Cobalt iP Digital
Point Motor
On-Off Toggle
RE-SET
Switch connected
to GND & Input 1
DCC COMMAND STATION
with FIVE AMP POWER BOOSTER
CONTROL
BUS
CAB BUS
PROGRAM
TRACK
STATUS
STATUS TRACK
PH-PRO
6pin RJ12 Cable
Cobalt iP Digital
Point Motor
Set to
DCCconcepts Super Panel Point Motor Control Manual V1.0 March 2024
NCE PowerCab
Handset
PUSH
6pin RJ12
12V DC
Flat Cable
CAB OUT
CAB IN
PROGRAM
Track/Power Bus
NCE ProCab
Handset
PUSH
6pin RJ12
12V DC
Flat Cable
CAB OUT
CAB IN
PROGRAM
Track/Power Bus
DCC COMPATIBLE COMMAND CONTROL
DCC CONCEPTS V1.
SUPER PANEL 021
NCE
CAB
DIRECTION
MOMENTUM
SPEED
INC FAST
INC
DEC FAST
DEC
HORN/
WHISTLE
BELL
HEADLIGHT
EMERGENCY
STOP
OPTION
RECALL
SELECT
SELECT
LOCO
MACRO
ACCY
1
2
3
4
5
6
7
8
9
0
ENTER
CONSIST
SETUP
CLEAR
ADD
DEL
PROG/
ESC
EXPN
28/128
SHIFT
F10
F11
F12
DCC COMPATIBLE COMMAND CONTROL
LOC:8450 12:54AM
FWD: 000
L-----6
NCE
PROCAB
DIRECTION
MOMENTUM
SPEED
INC FAST
INC
DEC FAST
DEC
HORN/
WHISTLE
BELL
HEADLIGHT
EMERGENCY
STOP
OPTION
RECALL
SELECT
SELECT
LOCO
MACRO
ACCY
1
2
3
4
5
6
7
8
9
0
ENTER
CONSIST
SETUP
CLEAR
ADD
DEL
PROG/
ESC
EXPN
28/128
SHIFT
F10
F11
F12
Need help?
Do you have a question about the Super Panel and is the answer not in the manual?
Questions and answers