Appendix; Stop Local Off; On-Screen Error And Info Messages - Viscount Cantorum Duo Plus Reference Manual

Hide thumbs Also See for Cantorum Duo Plus:
Table of Contents

Advertisement

Appendix

APPENDIX

Stop Local Off

Setting a stop in Local Off mode means that it will not be played by the organ's internal sound generation system,
but the relative MIDI (System Exclusive code) message will be transmitted, so that it can be turned on and played
on a connected instrument.
To set a stop in Local Off mode, while the main screen is on the display, press the
[S] thumb piston, keep it pressed and also press the [C] thumb button. The Leds
of all the stops will light up and the display will show a pop-up. After setting the
setup required, press [S] and [C] together to save it.
Accessing the Local Off setting function after this will trigger display of the status
of the stops as follows:
Light on: stop in Local On mode (plays with internal generation)
Light off: stop in Local Off mode

On-screen error and info messages

Message
Going on with one missing
sound
module,
please
don't use a full organ
registration
Keyboards and panel not
present
Sound modules malfunction
Filesystem error
No files found
USB pen not found
No USB pen attached
File load failed
Can't open file
File load failed
Can't read file's header
File load failed
File's length check failed
File load failed
Invalid version number
File load failed
Invalid file's checksum
Error
Snapshot file is corrupted
Error
Different organ model
Error
Invalid file version
Different stop list found.
Replace pipe sets anyway?
Reference Manual
Description
A DSP module is no longer functional. The organ can still be played (press [EXIT] at the
displayed message) but it is advisable not to use a full stop registration due to the reduced
polyphony. Contact the technical support service at the e-mail address service@viscount.it
as soon as possible to replace the faulty DSP module.
The system cannot contact one or more peripheral micros. Contact the technical support
service at the e-mail address service@viscount.it.
The system cannot start one or more sound modules. The organ cannot be switched on.
The acronym "KO" and six asterisks indicate malfunctioning modules. Contact the technical
support service at the e-mail address service@viscount.it. Remember to write down the
error message.
Reading error of the current memory unit. If this occurs with a USB flash drive, try
disconnecting and then connecting it again shortly thereafter. If this doesn't work, try
formatting the flash drive using a computer. If this occurs with the internal memory, try again
or contact the technical support at the e-mail address service@viscount.it.
There are no files of that type in the current memory.
The system does not detect the USB flash drive that is necessary for the current operation.
If the correct USB flash drive is connected to the instrument, disconnect it then connect it
again. Also check that the flash drive is formatted correctly with the FAT32 file system and
that it is undamaged.
The system failed to load the .CMB file, the desired file could not be opened.
The file system in the USB flash drive could be corrupted. Try to re-copy the file in the USB
flash drive or to format it.
The system failed to load the .CMB file, its header is impossible to read.
The file system in the USB flash drive could be corrupted. Try to re-copy the file in the USB
flash drive or to format it.
The .CMB file load failed because the actual file length is different from what stated in the
header. The file system in the USB flash drive could be corrupted. Try to re-copy the file in
the USB flash drive or to format it.
.CMB file load failed because the file has been generated with a newer and/or not
compatible release of the operating system.
The system could not load the .CMB file. The checksum test failed. The file or file system
in the USB flash drive could be corrupted. Try to re-copy the file in the USB flash drive or
to format it.
The system could not load the .ALL file. The file or file system in the USB flash drive could
be corrupted. Try to re-copy the file in the USB flash drive or to format it.
The system could not load the .ALL file because it has been created with a different organ
It is not possible to load a .ALL file created with a different organ model.
model.
.ALL file load failed because the file has been generated with a newer and/or not compatible
release of the operating system.
You are loading a .ALL file (using the Entire Snapshot or Only Pipesets options) containing
a different stop list, one or more stop label will not match with the played voice (and so
possibly you will have to move the labels). Press [MENU/ENTER] to confirm the load or
[EXIT] to quit.
EN - 42

Advertisement

Table of Contents
loading

Table of Contents