Gree GWC09ATBXB-K6DNA1C/I Owner's Manual page 14

Table of Contents

Advertisement

3.
Remove the wire clip; connect the power conn-
ection wire to the wiring terminal according to
the color; tighten the screw and then fix the po-
wer connection wire with wire clip.
09K:
N(1)
yellow-
blue black
green
Outdoor unit connection
12K 24K 28K:
N(1)
2 2
blue black brown
Outdoor unit connection
NOTICE
The wiring board is for reference only, please refer
to the actual one.
4.
Put wiring cover back and then tighten the screw.
5.
Close the panel.
Step 8:
Bind up pipe
1.
Bind up the connection pipe, power cord and
drain hose with the band.
indoor unit
gas
pipe
band
2.
Reserve a certain length of drain hose and
power cord for installation when binding th-
em. When binding to a certain degree, sep-
arate the indoor power and then separate
the drain hose.
2 2
3
brown
3
yellow-
green
indoor and
outdoor power cord
liquid pipe
drain hose
9
connection pipe
indoor power cord
3.
Bind them evenly.
4.
The liquid pipe and gas pipe should be bo-
und separately a t the end.
NOTICE
The power cord and control wire can't be crossed or
winding.
The drain hose should be bound at the bottom.
Step 9:
Hang the indoor unit
1. Put the bound pipes in the wall pipe and then
make them pass through the wall hole.
2.
Hang the indoor unit on the wall-mounting
frame.
3.
Stuff the gap between pipes and wall hole
with sealing gum.
4.
Fix the wall pipe.
5.
Check if the indoor unit is installed firmly and
closed to the wall.
indoor
wall pipe
lower hook of
wall-mounting frame
NOTICE
Do not bend the drain hose too excessively in order
to prevent blocking.
drain hose
band
outdoor
sealing gum
upper hook

Advertisement