TROUBLESHOOTING YOUR JET PLANT AND EQUIPMENT
Symptom
Aerator not functioning
Aerator functioning intermittently
Control Panel Alarm Active
Effluent has strong odor
Sewage odors indoors
For additional information on Jet systems reference the FAQ section on our web site at
REV 2014/11/20
Probable Cause
No power to control panel
Mini-breaker tripped
Aerator failure
High water in treatment tank
Thermal breaker engaged
Aerator not functioning
Aerator not installed in system
Secondary alarm activated
Bacteria not present/dead
Aerator not functioning
Media pack requires service
Hydraulic/Organic Overload
Improper plumbing installations
Roof vents clogged
Poor/Bad wax seal on toilets
Jet, Inc. • 750 Alpha Drive • Cleveland, OH 44143 USA • 440.461.2000 Fax 440.442.9008 • email@jetincorp.com • www.jetincorp.com
Correction
Check main house breaker
Reset mini breaker on Jet control panel
Replace unit, contact service provider
Check discharge field or pump tanks
Load on aerator shaft, contact service
provider
See above
Install/replace aerator
Check auxiliary devices
Allow system to regenerate bacteria, if
problem persists for over 48 hours pump
tank and seed with BIO-JET7®
See above
Contact service provider, have system
serviced and pumped
Reduce overload conditions by altering
water use patterns
Check plumbing and ensure traps have
water
Check vents
Replace wax ring seals
www.jetincorp.com
JET, JET AERATION, BAT, AIR-SEAL, JET CHLOR, CHLOR AWAY, and BIO JET-7 are registered trademarks of JET, INC.