Jet 952 Installation Instructions Manual

Uv disinfection device

Advertisement

Quick Links

COMPONENTS
The following components are supplied in
the disinfection system:
1. Control Panel
2. 4" ABS riser pipe
3. UV Housing with 4" ABS cap, 4" ABS
pipe, 4" double sanitary tee, spacer
insert and keyway
4. UV Insert with top and bottom
plates, H-Chanel risers, quartz
tube and lifting handle
5. UV lamp - 37 Watts
The following components should be
supplied by the installer:
1. All-Purpose Cement
2. Clear Cleaner for plastics
3. Drill with Universal Bit
4. Clean soft cloth
5. Isopropyl alcohol
6. Small slotted screwdriver
7. Wire strippers
8. Phillips Screwdriver
9. Water tight conduit connectors
10. Conduit and Wiring
WARNING: Exposure to UV light
is harmful. Immediate or prolonged
exposure to UV light can result in
painful eye injury, skin burn, premature
skin aging, or skin cancer. Do not
remove an active UV lamp from the UV
housing or attempt to activate lamps
which are not installed within the UV
housing.
JET Model 952 UV Disinfection
Device Installation Instructions

Advertisement

loading

Summary of Contents for Jet 952

  • Page 1 JET Model 952 UV Disinfection Device Installation Instructions COMPONENTS The following components are supplied in the disinfection system: 1. Control Panel 2. 4” ABS riser pipe 3. UV Housing with 4” ABS cap, 4” ABS pipe, 4” double sanitary tee, spacer insert and keyway 4.
  • Page 2: Installation Instructions

    JET Model 952 UV Disinfection Device Installation Instructions INSTALLATION INSTRUCTIONS EXCAVATION 1. Excavation should be made as close as possible to the effluent end of the treatment plant. 2. Excavation(s) should be as minimal as possible to reduce settling of backfill.
  • Page 3 JET Model 952 UV Disinfection Device Installation Instructions UV INSERT INSTALLATION 1. Place the 1” Schedule 40 PVC pipe in the coupler of the UV insert to help determine where the 1” pipe should be trimmed so that it is easily reached when in the riser.
  • Page 4 NOTE: ONLY PROPER SIZE WATERTIGHT terminal. HUB AND FITTINGS CAN BE USED WHEN ATTACHING CONDUIT AND WIRING TO THE CONTROL PANEL. Jet recommends using Carlon or T&B liquidtight non metallic conduit and fittings for field installations. Verify all connections are properly installed and watertight.
  • Page 5: Uv Lamp Installation

    SERVICE PROCEDURES 1. Apply dielectric grease onto the face of the four pin connector of the power cable Jet recommends servicing the UV system at a to protect against moisture and corrosion. minimum every six months. 2. You do not want to touch the UV lamp surface with your hands.
  • Page 6 Troubleshooting Guide for Jet Model 952 UV Disinfection Device Solution Problem Probable Cause Excess Wire Tension On Union • Excess wire between cord grip • Loosen cord grip and adjust length of and UV lamp connector wire to match Lamp Insert handle Control Panel Not Seating • Excess wire not stored in UV...
  • Page 7: Year Limited Warranty

    Jet distributor who is in good standing with Jet Inc. Jet Inc. may, at its option, elect to repair or replace the defective components, or refund the purchase price of the defective component(s). The system owner shall assume all responsibility for freight charges to and from Jet Inc. This warranty does not cover system components or parts that have been (I) damaged due to disassembly by unauthorized persons, improper installation, misuse, or lightning, (II) subjected to external damage, (III) damaged due to improper or altered wiring, or overload protection, or (IV) damaged by failure to follow the suggestions outlined in any associated product documentation or Owners Manuals. Items normally consumed in service such as fuses, filter cartridges, spin plates, grease, oil, etc. are not warranteed.