TANK PUMPING INSTRUCTIONS

Media Compartment Pumping 500 Thru 1500 GPD
Plants:
1.
Jet service technicians must air clean the media tank prior to
tank pumping. Pumping must take place within two weeks after
media cleaning.
2.
Remove tank access covers. Remove aerator(s). Always place
aerator so shaft and foam restrictor do not contact any surface.
You can lean aerator against the mounting casting as long as
the shaft does not come into contact with hard surfaces. Even a
small bend in the shaft will shorten the aerator's lifespan.
3.
Always pump the Pretreatment Compartment (access 1) first,
then pump the Treatment Compartment (access 2) second.
Pumping from the Settling Compartment (access 3) is not
required.
4.
The opening in some media is very small. Take extreme care
not to touch any part of the media with the pump hose or the tip
of the pump hose - serious damage can occur if the media is
stressed by the vacu-um or the hose.
5.
The opening in the media center can not be seen from the
surface. Care-fully lower the hose down the center of the
mounting casting, through the opening in the media, and down
to the bottom of the tank.
6.
Pump tank until empty and carefully remove hose. Use caution
not to touch the media with the hose as the hose is being
removed.
7.
Rinse out all compartments and pump out residual water.
8.
Reinstall aerator(s) and access covers.
Note: Tank pumping should only be performed by a properly
equipped professional service provider. Check with your local
health department for current tank pumping regulations.
**The plastic tank must be filled with water immediately after
pumping.
REV 2014/11/20
BAT® MEDIA
Jet, Inc. • 750 Alpha Drive • Cleveland, OH 44143 USA • 440.461.2000 Fax 440.442.9008 • email@jetincorp.com • www.jetincorp.com
ACCESS COVERS
500, 600, 750 & 800 GPD
There are three access covers. Pump from
access cover one and two.
1
1000, 1250 & 1500 GPD
These systems have two sets of media,
use caution when pumping from riser one and two. There is also
a separate pre-treatment tank that will require pumping.
1
JET, JET AERATION, BAT, AIR-SEAL, JET CHLOR, CHLOR AWAY, and BIO JET-7 are registered trademarks of JET, INC.
2
3
2
3
QA-SAL-102