PSG-7 OIL/WATER SEPARATOR INSTALLATION, OPERATION, MAINTENANCE MANUAL FAILURE TO READ AND UNDERSTAND THE FOLLOWING INSTRUCTIONS MAY CAUSE YOU UNNECESSARY COMPLICATIONS IN THE INSTALLATION OR OPERATION OF THIS EQUIPMENT. More Than Air. Answers. Online answers: www.ingersollrandproducts.com PHONE: 1-800-526-3615 CCN: 38463311 Rev. B...
1.0 HOW IT WORKS 2.0 INSTALLATION The oil-contaminated water from the compressed air The separator should be placed in a leveled position. system is discharged from a condensate drain into the Remove the 3 knobs on the top of the unit and remove separator ().
Weekly, collect a sample of the discharge water in a NOTE: clear glass vessel and, compare it to tap water, checking The PSG-7 separator cannot be used with 00% food grade for cloudiness. lubricants and/or silicon based lubricants. Replace the adsorption module when cloudiness CCN for the PSG-7 (3845699).
6.0 GENERAL DATA CONDENSATE INLET FOUR (4) - 1/2" NPT FILTER ELEMENT 10.4 ADSORPTION MODULE WATER OUTLET 1/2" NPT 16.2 14.3 10.4 SERVICE DRAIN 1/4" NPT...
Page 8
Mounting Instructions for PSG-7 Using Optional Mounting Bracket Locate a mounting position that provides access to the separator. NOTE: The bracket can be mounted in either position illustrated in Figure or . Make a copy of the attached template sheet.