INSTALLATION MANUAL
R-410A
OUTDOOR SPLIT-SYSTEM
AIR CONDITIONING
MODELS: 18 SEER - CZE03811 SERIES
3 TON
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
UNIT INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INSTALLATIONS REQUIRING TXV . . . . . . . . . . . . . . . . . . . . . . . . . . 4
ELECTRICAL CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Typical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Tubing Hanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Underground Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Heat Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Typical Field Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
R-410A Saturation Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
18Z38AC Subcooling Charging Chart . . . . . . . . . . . . . . . . . . . . . . . . . 8
SECTION I: GENERAL
The outdoor units are designed to be connected to a matching indoor
coil with sweat connect lines. Sweat connect units are factory charged
with refrigerant for the smallest rated indoor coil plus 15 feet of field
supplied lines.
Matching indoor coils are available with a thermal expansion valve or
an orifice liquid feed sized for the most common usage. The orifice size
and/or refrigerant charge may need to be changed for some system
combinations, elevation differences, or total line lengths. See Tabular
Data Sheet provided in unit literature packet for charge requirements.
Refer to Application Data covering "General Piping Recommendations
and Refrigerant Line Length" (Part Number 036-61920-001).
SECTION II: SAFETY
This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.
Understand and pay particular attention to the signal words DANGER,
WARNING, or CAUTION.
DANGER indicates an imminently hazardous situation, which, if not
avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation, which, if not
avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation, which, if not
avoided may result in minor or moderate injury. It is also used to
alert against unsafe practices and hazards involving only property dam-
age.

TABLE OF CONTENTS

EVACUATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
SYSTEM CHARGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
SYSTEM START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
LIST OF FIGURES
CFM Selection Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Thermostat Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
LIST OF TABLES
Diagnostic Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Improper installation may create a condition where the operation of
the product could cause personal injury or property damage.
Improper installation, adjustment, alteration, service, or mainte-
nance can cause injury or property damage. Refer to this manual
for assistance or for additional information, consult a qualified con-
tractor, installer, or service agency.
This product must be installed in strict compliance with the
enclosed installation instructions and any applicable local, state,
and national codes including, but not limited to building, electrical,
and mechanical codes.
R-410A systems operate at higher pressures than R-22 systems.
Do not use R-22 service equipment or components on R-410A
equipment. Service equipment
INSPECTION
As soon as a unit is received, it should be inspected for possible dam-
age during transit. If damage is evident, the extent of the damage
should be noted on the carrier's delivery receipt. A separate request for
inspection by the carrier's agent should be made in writing. See Local
Distributor for more information.
R
P
CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE
SYSTEM IS LISTED
WITH ARI.
ISO 9001
LISTED
Certified Quality
Management System
Must Be Rated
for R-410A.
103142-YIM-A-1204

Advertisement

Table of Contents
loading

Summary of Contents for York CZE03811 Series

  • Page 1: Table Of Contents

    R-410A OUTDOOR SPLIT-SYSTEM AIR CONDITIONING CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. MODELS: 18 SEER - CZE03811 SERIES 3 TON ISO 9001 LISTED Certified Quality Management System TABLE OF CONTENTS GENERAL ..........1 EVACUATION .
  • Page 2: Unit Installation

    103142-YIM-A-1204 Requirements For Installing/Servicing R-410A Equipment The outdoor unit must have sufficient clearance for air entrance to the condenser coil, for air discharge, and for service access. See Figure 1. • Gauge sets, hoses, refrigerant containers, and recovery systems must be designed to handle POE oils and the higher pressures of NOTE: For multiple unit installations, units must be spaced a minimum R-410A.
  • Page 3: Tubing Hanger

    103142-YIM-A-1204 GROUND INSTALLATION NOTE: Using a larger than specified line size could result in oil return problems. Using too small a line will result in loss of capacity The unit may be installed at ground level on a solid base that will not and other problems caused by insufficient refrigerant flow.
  • Page 4: Installations Requiring Txv

    103142-YIM-A-1204 Protect the vapor valve with a wet rag and braze the vapor line connection to the outdoor unit. The nitrogen flow should be exiting the system from the vapor service port connection. After this con- nection has cooled, remove the nitrogen source from the liquid fit- Dry nitrogen should always be supplied through the tubing while it ting service port.
  • Page 5: Electrical Connections

    103142-YIM-A-1204 Install TXV equalizer line in 1/8” hole previously made in vapor Remove the service access panel to gain access to the unit wiring. line. Equalizer line should not be bottomed out in the vapor line. Route wires from disconnect through power wiring opening pro- Insert equalizer line at least 1/4”...
  • Page 6: Evacuation

    103142-YIM-A-1204 DEHUMIDIFICATION CONTROL VARIABLE 2 -STAGE A dehumidification control accessory 2HU06700124 may be used with SPEED THERMOSTAT AIR CONDITIONER AIR HANDLER variable speed air handlers or furnaces in high humidity areas. This control works with the variable speed indoor unit to provide cooling at a reduced air flow, lowering evaporator temperature and increasing latent BLU/YEL capacity.
  • Page 7: System Start-Up

    103142-YIM-A-1204 SECTION VIII: SYSTEM START-UP INDICATIONS OF PROPER OPERATION Refrigerant charging should only be carried out by a qualified air Cooling conditioning contractor. The outdoor fan should be running, with warm air being dis- charged from the top of the unit. Measurement Method The indoor blower (furnace or air handler) will be operating, dis- If a calibrated charging cylinder or accurate weighing device is avail-...
  • Page 8: R-410A Saturation Properties

    103142-YIM-A-1204 TABLE 1: R-410A Saturation Properties PRESSURE PRESSURE PRESSURE PRESSURE PRESSURE TEMP. °F TEMP. °F TEMP. °F TEMP. °F TEMP. °F PSIG PSIG PSIG PSIG PSIG 129.70 169.60 217.40 274.10 340.50 132.20 172.60 220.90 278.20 345.30 134.60 175.50 224.40 282.30 350.10 137.10 178.50...
  • Page 9: Diagnostic Label

    103142-YIM-A-1204 TABLE 3: Diagnostic Label Status LED Status LED Description Status LED Troubleshooting Information Green “POWER” Module has power Supply voltage is present at module terminals 1. Compressor protector is open 2. Outdoor unit power disconnect is open Thermostat demand signal Y1 is present, 3.
  • Page 10: Wiring Diagram

    103142-YIM-A-1204 SECTION IX: WIRING DIAGRAM FIGURE 10: Wiring Diagram Unitary Products Group...
  • Page 11 103142-YIM-A-1204 NOTES Unitary Products Group...
  • Page 12 Subject to change without notice. Printed in U.S.A. 103142-YIM-A-1204 Copyright © by York International Corp. 2004. All rights reserved. Supersedes: Nothing Unitary 5005 Norman Product York Group Drive 73069...

Table of Contents