INSTRUCTIONS TO USERS

Please read the "Instruction Manual " carefully prior to the use of your air conditioner so as to ensure
proper operations.

INSTRUCTIONS FOR INSTALLATION

Make sure to have the professional after-sale service persons of our company or the authorized
dealers to install the units before you use.
The units are not to be installed at places where there might be
leakage of combustible gases.
After the connecting of the wires between the indoor unit and the
outdoor unit, check whether the connecting is loose or not by pulling
the wire with a little force.

INSTRUCTIONS FOR OPERATION

Never try to stop the operation of the air
conditioner by pulling out the power supply
line.
Such performance
might cause
electric shock or
fire hazards.
Do not operate the switch by wet hands.
It might cause electric shocks.
In case that the leaked
gas accumulates around
the units, there might
occur the accident of fire
hazards.
The loose connecting might
result in fire hazard..
Do not connect the power supply line to an
intermediate connector. Use of prolonged
power line is strictly forbidden.
Nor is it allowed to share the same plug
connector with other electric appliances.
It might cause electric shocks,
overheating, fire hazards or
other accidents..
Before the connector is plugged in, please
make sure that there is no dust on it and that
it is plugged fully in place.
If there is dust on the plug or
if the plug is not in place, i t
might cause electric shocks
or fire hazards.
33
Make sure that the earth leakage-circuit breaker is installed.
Absence of the earth leakage-circuit breaker might lead to electric
shock and some other hazards.
Make sure that the air conditioner is properly grounded.
Improper grounding might cause electric shocks or other hazards.
Do not press, stretch, damage, heat or modify
the power line.
be replaced due to some other reasons,
please make sure to have dealer or the
authorized maintenance people to do the
replacement.
Never use the fuse with incorrect capacity or
any other metal wires.
copper wires for fuse might cause operational
failures or fire hazards.
Earth leakage
circuit breaker
IlThe grounding
wire on the air
conditioner
should be
tightly
connected to
the ground of
the power
source.
It might cause
electric shocks,
overheating, fire
hazards, etc. If the
power line wire is
damaged or needs to
copper
wire
The use of metal or