Product Description; Product Range; Matched Pairs Of Compressor And Drive - Emerson Copeland YHV029RG Application Manuallines

Scroll variable-speed compressors for heat pump applications
Table of Contents

Advertisement

2

Product description

2.1

Product range

These application guidelines cover Copeland scroll variable-speed compressor models
YHV*RG and YHV*RT for heat pump applications. Compressors YHV*RG f or use with R290
ref rigerant have a speed range of 1100 to 5500 rpm. Compressors YHV*RT f or use with R454C
ref rigerant have a speed range of 1300 to 5500 rpm. They f eature a three-phase brushless
permanent magnet (BPM) motor which is controlled by an Emerson ED3 or EV3 motor control drive,
ref erred to as the "ED3/EV3 drive" or "drive" throughout these guidelines.
Figure 1: YHV*RG compressor
Compressor
YHV029*-9X9
ED3015AU
YHV046*-9X9
ED3020AU
YHV046*-4X9
YHV046*-9X9
EV3057B
YHV072*-9X9
ED3020AU
YHV072*-4X9
EV3057B
** Refrigerant dew temperature, evaporating temperature: -15 °C; condensing temperature: 35 °C; suction gas
superheat: 5 K; liquid sub-cooling: 4 K, ratings based on compressor only measurements
Table 1: Heating capacity in kW according to refrigerant used
NOTE: For more information on the motor control drive please refer to the ED3 & EV3 User
Manuals.
2.2

Matched pairs of compressor and drive

The YHV*RG/RT compressors with motor code "X9" are unprotected compressors and are offered
in matched pairs with the ED3 or EV3 drive, designed in accordance with EN 60335-1. The motor
protection is implemented in the ED3/EV3 drive.
The matched pairs have been designed for maximum efficiency and reliability. The drive will power
the compressor, control the compressor running speed, provide compressor and drive protection and
communicate with the master controller in Modbus RTU protocol. The drive requires cooling and is
typically installed in the unit near the compressor. To optimize drive ef f icienc y and to limit
electromagnetic interferences, the drives have to be installed with all mandatory accessories as per
the ED3 & EV3 User Manuals.
4
Figure 2: YHV*RT compressor
Heating capacity** (kW)
at maximum speed
Drive
R290
6.2
9.7
-
9.7
9.7
16.4
16.4
Figure 3: ED3 drive
R454C
6.2
9.7
9.7
9.7
14.2
14.2
AGL_HP_VS_YHV_RG_RT_EN_Rev00
Figure 4: EV3 drive