Installing Calibration Files; Calcmet Software Configuration; Connecting Sample Lines; Table 3. List Of Files After Calcmet Setup - Gasmet GT5000 Instructions And Operating Manual

Terra ftir gas analyzer
Hide thumbs Also See for GT5000:
Table of Contents

Advertisement

CalibrationInfo.dat
CALCMET.BKGX
Version history.txt

Table 3. List of files after Calcmet setup.

Once the files have been installed, it will still be necessary to set the reference spectrum libraries
(calibrations), and other settings to make the measurements and analysis. Refer to the later
chapters of this manual for description on setting all the analysis and measuring parameters.
The installation also includes the default library and some demo libraries tailored for different
applications. These are for demonstration and training purposes only and should not be used for
analyzing any real measurements.
All the demo library files can be found in C:\CalcmetDemoLib\ and the reference spectra for the
demo libraries are situated in respective sub folders under the same path. During software
installation setup the user can choose not to install the demo libraries, if desired.
An optional compiled html help file (Calcmet.chm) on the Calcmet program features can also be
dropped into the installation folder for quick reference. The in-program help is accessible from the
'F1' key or by clicking help menu option.

5.2.1. Installing calibration files

Optionally there can be analyzer specific calibrations supplied with the analyzer. To use the
calibrations, copy the folder including the reference spectra and the .CLIB file under the C:/ from
Gasmet USB.
If the reference spectrum files (*.REFX) and library files (*.CLIB) were copied from the Gasmet USB,
it may be that the files are write protected. To later make any changes to settings, it will be
necessary to deactivate write protection from these files. This can be done by opening the file
properties of all these files and unchecking the "Read-Only" option.

5.2.2. Calcmet Software Configuration

When the Calcmet software starts, a welcome window "Welcome to Calcmet" appears. You can
select the communication mode and the corresponding settings. Click OK.
If you have a Calcmet Expert License Key, insert it now.

5.3. Connecting sample lines

There are four gas inlet/outlet fittings in the front panel. Connect sample inlet tubing to the Sample
in, nitrogen for background measurement to Zero gas, possible sample outlet to Sample out and
possible purge gas to the Purge air. All the fittings are quick-connect fittings. To connect a line,
make sure that the collar is pressed in before inserting the line. The line is properly connected when
the collar releases from the pressed in state. To disconnect, release the line by pressing the collar of
the fitting and pull the tube gently out.
Gasmet GT5000 Terra Instruction and Operating Manual
CalibrationInfo.dat
CALCMET.BKGX
Version history.txt
Latest calibration information
(example)
Latest background (example)
Version information text file
16