DataCan LineWise AE304UU0002 User Manual page 19

Table of Contents

Advertisement

Item
Description
3.
Allows the user to set the maximum value that appears on the left Y axis of the graph
report.
The find button retrieves the maximum point in the data.
The Max: input field allows the user to type the maximum value to appear on the
graph report.
The Preset Limit button allows the user to access a list of commonly used maximum
values.
4.
Shows and hides the units for the current traces. Hide the units if you have more than
one trace on one side, and type a description in the Label field.
5.
Auto # of Intervals determines how many major horizontal divisions appear on the
graph. When the function is active, the program determines the number of divisions.
When the function is inactive, the user can set the number of divisions manually. The
user must click the AutoScale button when the function is active.
The check box activates or deactivates the auto function for the current graph re-
port.
The input field allows the user to define the number of intervals manually.
The Preset Limit button allows the user to access a list of commonly used interval
values.
NOTE: If Auto Intervals is set on the Preferences dialog box, then this dialog box will be
overridden. Also, if Continuous Update is selected on the Preferences dialog box during
real-time logging, the values in this dialog box will be overridden.
6.
Auto Interval Size determines the intervals for the values that appear on the Y axis.
When the function is active, the program rounds the intervals to values that make the
graph easier to read. When the function is inactive, the user can set the interval size
manually. The user must click the AutoScale button when the function is active.
The check box activates or deactivates the auto function for the current graph
report.
The input field allows the user to define the interval size manually.
The Preset Limit button allows the user to access a list of commonly used intervals.
7.
Click this button to perform the active AutoScale functions for the current graph report
(see items 5 and 6). AutoScale rounds the intervals and interval size to make the graph
easier to read.
8.
Two traces are permitted on the left side of the graph, and two on the right side of the
graph (use the Right Side tab).
The first trace drop-down box determines the first trace that will appear on the graph
report. The first trace is considered the 'main' trace and min/max values are calcu-
lated from the data for the main trace only.
The disc icon allows the user to set the current trace settings as presets.
The unit drop-down box lets the user choose the units for the trace.
The line style drop-down box lets the user select a line style for the trace.
The colour drop-down box lets the user select a colour for the trace.
9.
This group controls the selection and formatting for the second trace. See item 8 for
more information.
10.
Presets the values to minimum and maximum data values.
11.
Select the Show Legend check box to display a legend of trace names on the graph
report.
12.
Accepts the current values and applies them to the graph report, then closes the dialog
box.
13.
Exits the dialog box without accepting any changes.
Property of DataCan Services Corp. No duplication or distribution without written consent
Property of DataCan Services Corp. No duplication or distribution without written consent
13

Advertisement

Table of Contents
loading

Related Products for DataCan LineWise AE304UU0002

This manual is also suitable for:

Linewise ae304uu0008

Table of Contents