Page 1
Edge Computing Appliance Platform Hardware Platforms for Edge Computing ECA-4035 User Manual Version: 1.0 Date of Release:2024-01-31...
Page 2
- assumed to be qualified in the servicing of computer equipment, such as professional system integrators, or service personnel and technicians. The latest version of this document can be found on Lanner’s official website, available either through the product page or through the Lanner Download Center page with a login account and password.
Page 3
ECA-4035 User Manual Contact Information Taiwan Corporate Headquarters China Lanner Electronics Inc. Beijing L&S Lancom Platform Tech. Co., Ltd. 7F, No.173, Sec.2, Datong Rd. Guodong LOFT 9 Layer No. 9 Huinan Road, Xizhi District, New Taipei City 22184, Huilongguan Town, Changping District, Beijing...
Page 5
ECA-4035 User Manual Safety Guidelines Follow these guidelines to ensure general safety: Keep the chassis area clear and dust-free during and after installation. Do not wear loose clothing or jewelry that could get caught in the chassis. Fasten your tie or scarf and roll up your sleeves.
Page 6
The installation of this product must be performed by trained specialists; otherwise, a non-specialist might create the risk of the system’s falling to the ground or other damages. Lanner Electronics Inc. shall not be held liable for any losses resulting from insufficient strength for supporting the system or use of inappropriate installation components.
Page 7
ECA-4035 User Manual temperature (Tma) specified by the manufacturer. Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of airflow required for safe operation of the equipment is not compromised. Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.
Page 8
ECA-4035 User Manual Electrical Safety Instructions Before turning on the device, ground the grounding cable of the equipment. Proper grounding (grounding) is very important to protect the equipment against the harmful effects of external noise and to reduce the risk of electrocution in the event of a lightning strike. To uninstall the equipment, disconnect the ground wire after turning off the power.
CHAPTER 1: PRODUCT OVERVIEW The ECA-4035 offers 8~22 cores of computing power and comes with 1x OCP 3.0 and 1x PCIe*16; the ECA- 4035 is designed for deployment either as edge AI servers for smart city applications, or as multi-access edge computing (MEC) servers for 5G edge cloud and vRAN/O-RAN platform for distributed units.
ECA-4035 User Manual Front Panel F5 F6 Description Power Supply 600W AC Power Supply LED Indicator System Power / System Status / Storage Status LED Indicators Reset Button For Software Reset (control by CPLD) Power Button 1x Power Button LOM Port 1x 1GbE RJ45 Management Port;...
ECA-4035 User Manual CHAPTER 2: MOTHERBOARD INFORMATION Block Diagram...
Page 16
ECA-4035 User Manual Motherboard Layout The motherboard layout shows the connectors and jumpers on the board. Refer to the following picture as a reference of the pin assignments and the internal connectors. FAN 2 FAN 5 FAN 4 FAN 1...
ECA-4035 User Manual CHAPTER 2: HARDWARE SETUP To reduce the risk of personal injury, electric shock, or damage to the system, please remove all power connections to shut down the device completely, and wear ESD protection gloves when conducting the steps in this chapter.
ECA-4035 User Manual Installing the System Memory ECA-4035A/D provides four DIMM DDR4 system memory, while ECA-4035B/C/E supports two DIMM DDR4 system memory. Please follow the instructions below to install the memory modules. 1. Power off the system and open the chassis.
ECA-4035 User Manual Installing M.2 Modules (Optional) This system accommodates two M.2 2280 M-Key slots, supporting one NVMe and one SATA for memory expansion. Please follow the instructions for installation. 1. Power down the system and open the chassis. 2. Locate the M.2 module slots on the motherboard.
ECA-4035 User Manual Installing the Disk Drives (Optional) This system supports a disk drive bay, suitable for two 2.5” HDD/SSD drives. Please follow the instructions to install the disk drives. 1. Power off the system and open the chassis HDD/SSD cover.
Page 27
ECA-4035 User Manual 6. Place the tray (with the disk drives now installed) back to the its original place inside the system. Secure with the original three (3) screws. 7. Then, lift the fan cover, and unscrew the cable tie screw.
ECA-4035 User Manual Installing Expansion Module (Optional) ECA-4035 comes with an optional PCIe x16 FH3/4L slot for GPU graphics card or accelerator card expansion. Please follow the instructions for installation. 1. Power off the system and open the chassis cover.
ECA-4035 User Manual Installing OCP NIC (Optional) The system supports one OCP NIC 3.0 module. Please follow the steps for installation. 1. Power off the system and open the chassis cover. 2. On the front panel, locate the OCP NIC module slot. Rotate clockwise and loosen the lock-screw and remove the door.
CHAPTER 3: REMOTE SERVER MANAGEMENT Overview This chapter will introduce the features of Lanner’s BMC firmware and how to perform server remote management through it. The BMC firmware implements IPMI 2.0 based on ASPEED service processor. It performs all the BMC management tasks defined by IPMI 2.0. BMC firmware runs an embedded web-server for full configuration using Web UI.
ECA-4035 User Manual BMC Firmware Functional Description System health monitoring The BMC implements system sensor monitoring feature. It could monitor voltage, temperature, and current of critical components. System Power Management The BMC implements chassis power and resets functions for system administrators to control and manage the system power behavior.
Page 32
ECA-4035 User Manual Keyboard, Video, Mouse (KVM) Redirection The BMC provides keyboard, video, and mouse (KVM) redirection over LAN. This application is • available remotely from the embedded web server. Support video recording, recorded videos to be downloaded & playable.
ECA-4035 User Manual IPMI Commands Support List COMMANDS NETFN IPM Device “Global” Commands Get Device ID APP (06h) Cold Reset APP (06h) Warm Reset APP (06h) Get Device GUID APP (06h) BMC Watchdog Timer Commands Reset Watchdog Timer APP (06h)
Page 34
ECA-4035 User Manual Delete SEL Entry Storage (0Ah) Clear SEL Storage (0Ah) Get SEL Time Storage (0Ah) Set SEL Time Storage (0Ah) Get SEL Time UTC Offset Storage (0Ah) Set SEL Time UTC Offset Storage (0Ah) LAN Device Commands Set LAN Configuration Parameters...
ECA-4035 User Manual Using BMC Web UI In the address bar of your Internet browser, input the IP address of the remote server to access the BMC interface of that server. Initial access of BMC prompts you to enter username and password. A screenshot of the login screen is given...
Page 36
ECA-4035 User Manual Default User Name and Password Username: admin Password: admin The default username and password are in lower-case characters. When you log in using the default username and password, you will get full administrative rights, and it will ask you to change the default password once you log in.
Page 37
ECA-4035 User Manual Wizard Welcome Page Introduction After the first-time login, you will see first time wizard welcome page as the following picture. Please press the “Next” button and configure your BMC step by step. On the “IPv4”, “IPv6” and “DNS” pages, you could specify the hostname and network settings of BMC.
Page 38
ECA-4035 User Manual Web UI Layout Introduction The BMC Web UI consists of various menu items: Menu Bar The menu bar displays the following: Dashboard Appliance – Sensor Reading Appliance – Event Log Appliance – Remote Media Settings Appliance – KVM RMedia Settings Appliance –...
Page 39
ECA-4035 User Manual A screenshot of the menu bar is shown below: Menu Bar Quick Button and Logged-in User The user information and quick buttons are located at the top right of the Web UI. User Information Logged-in user information: Click the icon to view the logged-in user information.
Page 40
ECA-4035 User Manual Logged-in user and its privilege level This option shows the logged-in username and privilege. There are four kinds of privileges: User: Only valid commands are allowed. Operator: All BMC commands are allowed except for the configuration commands that can change the behavior of the out-of-hand interfaces.
ECA-4035 User Manual CHAPTER 4: BIOS SETUP BIOS is a firmware embedded on an exclusive chip on the system’s motherboard. Lanner's BIOS firmware offering including market-proven technologies such as Secure Boot and Intel Boot Guard technology deliver solid commitments for the shield protection against malware, uncertified sequences and other named cyber threats.
ECA-4035 User Manual Main Page Setup main page contains BIOS information and project version information. Feature Description BIOS Vendor: American Megatrends Core Version: AMI Kernel version, CRB code base, X64 Compliancy: UEFI version, PI version BIOS Information BIOS Version: BIOS release version...
ECA-4035 User Manual Advanced Page Select the Advanced menu item from the BIOS setup screen to enter the “Advanced” setup screen. Users can select any of the items in the left frame of the screen.
Page 44
ECA-4035 User Manual Trusted Computing Feature Options Description Enables or disables BIOS support for security device. By Security Device Enabled disabling this function, OS will not show Security Support Disabled Device. TCG EFI protocol and INT1A interface will not be available.
Page 45
ECA-4035 User Manual Trusted Computing (TPM1.2) Feature Options Description Enables or disables BIOS support for security device. By Security Device Enabled disabling this function, OS will not show Security Support Disabled Device. TCG EFI protocol and INT1A interface will not be available.
Page 46
ECA-4035 User Manual Trusted Computing (TPM2.0)
Page 47
ECA-4035 User Manual Feature Options Description Enables or disables BIOS support for security device. By Security Device Enabled disabling this function, OS will not show Security Device. TCG Support Disabled EFI protocol and INT1A interface will not be available. Enabled SHA-1 PCR Bank Enables or disables SHA-1 PCR Bank.
Page 48
ECA-4035 User Manual Super IO Configuration...
Page 49
ECA-4035 User Manual Serial Port 1 Configuration Feature Options Description Enabled Serial Port Enables or disables Serial Port 1. Disabled Device Settings IO=3F8h; IRQ = 4...
Page 50
ECA-4035 User Manual Serial Port 2 Configuration Feature Options Description Enabled Serial Port Enables or disables Serial Port 2 Disabled Device Settings IO=2F8h; IRQ = 3...
Page 51
ECA-4035 User Manual NCT7904D HW Monitor Feature Options Description Smart Fan Mode None Smart Fan Parameters Configuration...
Page 52
ECA-4035 User Manual Smart Fan Mode Configuration Feature Options Description Manual Mode Smart Fan Mode Smart Fan Mode select Smart Fan Mode Target Temperature T1 Input Target Temperature (Range:0 - 127) Target Temperature T2 Input Target Temperature (Range:0 - 127)
Page 53
ECA-4035 User Manual Serial Port Console Redirection Feature Options Description COM0 Enabled Enables or disables Console Redirection Console Redirection Disabled Feature Options Description COM1 Enabled Enables or disables Console Redirection Console Redirection Disabled...
Page 54
ECA-4035 User Manual Console Redirection Settings Feature Options Description VT100: ASCII char set VT100 VT100+:Extends VT100 to support color, function keys, etc. VT100+ VT-UTF8:Uses UTF8 encoding to map Unicode chars onto 1 or Terminal Type VT-UTF8 more bytes ANSI ANSI: Extended ASCII char set...
Page 55
ECA-4035 User Manual Enables VT-UTF8 Combination Key Support for ANSI/VT100 VT-UTF8 Combo Disabled Key Support Enabled terminals With this mode enabled, only text will be sent. This is to capture Disabled Recorder Mode Enabled Terminal data. Disabled Resolution 100x31 Enables or disables extended terminal resolution...
Page 56
ECA-4035 User Manual Legacy Console Redirection Settings Feature Options Description Legacy Serial Select a COM port to display redirection of Legacy OS and COM0 Redirection Port Legacy OPROM Messages Legacy OS 80x24 On Legacy OS, the Number of Rows and Columns supported...
Page 57
ECA-4035 User Manual PCI Subsystem Settings Feature Options Description Enables or disables 64bit capable Devices to be Decoded in Above 4G Disabled Above 4G Address Space (Only if System Supports 64-bit PCI Decoding Enabled Decoding) Disabled If the system has SR-IOV capable PCIe Devices, this option...
Page 58
ECA-4035 User Manual USB Configuration Feature Options Description Enables Legacy USB support. Enabled Auto option disables legacy support if no USB devices are Legacy USB Support Disabled connected; Auto Disabledoption will keep USB devices available only for EFI applications. Enabled This is a workaround for OSes without XHCI hand-off support.
Page 59
ECA-4035 User Manual Network Stack Configuration Feature Options Description Disabled Network Stack Enables or disables UEFI Network Stack Enabled Disabled Enables Ipv4 PXE Boot Support. If IPV4 is disabled, PXE boot Ipv4 PXE Support Enabled option will not be created.
Page 60
ECA-4035 User Manual CSM Configuration Feature Options Description Disabled CSM Support Enables or disables CSM Support Enabled Do Not Launch Network UEFI Controls the execution of UEFI and Legacy PXE OpROM Legacy Do Not Launch Storage UEFI Controls the execution of UEFI and Legacy Storage OpROM...
Page 61
ECA-4035 User Manual NVMe Configuration...
Page 62
ECA-4035 User Manual Control Legacy PXE Boot Feature Options Description Disabled Control Legacy PXE LAN1 Select On Board LAN# Boot Boot from LAN2...
ECA-4035 User Manual Platform Configuration Select the Platform menu item from the BIOS setup screen to enter the Platform Setup screen. Users can select any of the items in the left frame of the screen. Feature Options Description PCH-IO None...
Page 64
ECA-4035 User Manual PCH Configuration Feature Options Description SATA Configuration None SATA devices and settings Power ON Restore AC Power Loss Power Off Select S0/S5 for ACPI state after a G3 Last State Quiet Serial IRQ Mode Configure Serial IRQ Mode.
Page 65
ECA-4035 User Manual PCH SATA Configuration Feature Options Description Disabled SATA Controller Enables or disables SATA Controller Enabled AHCI Configure SATA as This will configure SATA as RAID or AHCI. RAID...
Page 66
ECA-4035 User Manual Disabled Port 1/4/5 Enable or Disable SATA Port Enabled Disabled Hot Plug Designates this port as Hot Pluggable. Enabled If enabled for any of ports Staggerred Spin Up will be Disabled Spin Up Device performed and only the drive switch have this option enabled Enabled will spin up at boot.
Page 67
ECA-4035 User Manual Server ME Configuration...
ECA-4035 User Manual Socket Configuration Select the Socket menu item from the BIOS setup screen to enter the Socket Setup screen. Users can select any of the items in the left frame of the screen. Feature Options Description Displays and provides option to change the Processor...
Page 70
ECA-4035 User Manual Adjacent Cache Disabled = MLC Spatial Prefetcher (MSR 1A4h Bit[1]) Prefetcher Enabled Disabled Extended APIC Enables or disables extended APIC support Enabled Disabled Enable Intel® TXT Enables Intel(R) TXT Enabled Disabled Enables the Vanderpool Technology, which takes effect after Enabled reboot.
Page 71
ECA-4035 User Manual CPU Socket0 Configuration Feature Options Description 0: Enable all cores. FFFFFFFFFFF: Disable all cores least one Core Disable Bitmap core per CPU must be enabled. Disabling all cores is an (Hex) invalid configuration.
Page 72
ECA-4035 User Manual Memory Configuration Feature Options Description Auto 1200 1333 1400 1600 Memory 1800 Maximum Memory Frequency Selections in Mhz. Do not select Frequency 1866 Reserved 2000 2133 2200 2400 2600 Memory None Displays memory topology with DIMM population information...
Page 73
ECA-4035 User Manual IIO Configuration Feature Options Description Socket0 Configuration None None Intel® VT for Press <Enter> to bring up the Intel? VT for Directed I/O (VT- None Directed I/O (VT-d) d) Configuration menu. PCI-E ASPM This option enables / disables the ASPM support for all...
Page 74
ECA-4035 User Manual Socket0 Configuration Feature Options Description Socket 0 None Settings related to PCI Express Port 1A Port 1A Socket 0 None Settings related to PCI Express Port 2A Port 1C Socket 0 None Settings related to PCI Express Port 2C...
Page 75
ECA-4035 User Manual Intel® VT for Directed I/O (VT-d) Feature Options Description Intel® VT for Enable Press <Enter> to bring up the Intel® VT for Directed I/O Directed I/O (VT-d) Disable (VT-d) Configuration menu.
Page 76
ECA-4035 User Manual Advanced Power Management Configuration Feature Options Description CPU P P State Control Configuration Sub Menu, include Turbo, XE None State Control etc. CPU C None CPU C State setting State Control...
Page 77
ECA-4035 User Manual CPU P State Control Feature Options Description Disabled SpeedStep (Pstates) Enables or disables EIST (P-States) Enabled Max Performance Boot Performance Max Efficient Select the performance state that the BIOS will set Mode Set by Intel Node before OS hand off.
Page 78
ECA-4035 User Manual CPU C State Control Feature Options Description CPU C1 Disabled Autonomous Core C-State Control Auto Demotion Enabled Disabled CPU C6 Report Enables or disables CPU C6(ACPI C3) report to OS Enabled Enhanced Halt State Disabled Core C1E auto promotion Control. Takes effect after reboot.
ECA-4035 User Manual Server Mgmt Feature Options Description Enabled BMC Support Enable or disables interfaces to communicate with BMC. Disabled Wait For BMC response for specified time out. In PILOTII, Enabled BMC starts at the same time when BIOS starts during AC...
Page 80
ECA-4035 User Manual 5 minutes OS Wtd 10 minutes Configure the length of the OS Boot Watchdog Timer. Not Timer Timeout 15 minutes available if OS Boot Watchdog Timer is disabled. 20 minutes Do Nothing Configure how the system should respond if the OS Boot...
Page 81
ECA-4035 User Manual System Event Log Feature Options Description Disabled Enables or disables all features of System Event Logging SEL Components Enabled during boot. Erase SEL Yes, On next reset Choose options for erasing SEL. Yes, On every reset Do Nothing...
Page 82
ECA-4035 User Manual BMC Network Configuration Feature Options Description Select to configure LAN channel parameters statically or Unspecified Configuration Address dynamically (by BIOS or BMC). The unspecified option Static source will not modify any BMC network parameters during DynamicBmcDhcp BIOS phase.
Page 83
ECA-4035 User Manual View System Event Log...
ECA-4035 User Manual Security Select the Security menu item from the BIOS setup screen to enter the Security Setup screen. Users can select any of the items in the left frame of the screen. Feature Description If ONLY the Administrator's password is set, it only limits access to Administrator Password Setup and is only asked for when entering Setup.
Page 85
ECA-4035 User Manual Secure Boot Feature Options Description Secure Boot is activated when Platform Key (PK) is enrolled, System Disabled Secure Boot mode is User/Deployed, and CSM function is disabled. Enabled Secure Boot mode selector: Secure Boot Standard In Custom mode, Secure Boot Variables can be configured without...
Page 86
ECA-4035 User Manual Key Management Feature Options Description Factory Key Disabled Provision factory default keys on next re-boot only when Provision Enabled System in Setup Mode. Restore Factory Force System to User Mode. Configure NVRAM to contain None keys OEM-defined factory default Secure Boot keys.
ECA-4035 User Manual Boot Select the Boot menu item from the BIOS setup screen to enter the Boot Setup screen. Users can select any of the items in the left frame of the screen. Feature Options Description The Number of seconds to wait for setup activation key.
ECA-4035 User Manual Save & Exit Select the Save and Exit menu item from the BIOS setup screen to enter the Save and Exit Setup screen. Users can select any of the items in the left frame of the screen.
Page 89
ECA-4035 User Manual ■ Save Changes and Reset When Users have completed the system configuration changes, select this option to save the changes and exit from BIOS Setup in order for the new system configuration parameters to take effect. The following window will appear after selecting the “Save Changes and Exit”...
ECA-4035 User Manual CHAPTER 5: BROADCOM CLI SETUP This section describes how to setup Broadcom Command Line Interface (CLI) via network. 1. X86 ethernet enp182s0f0(pci bus b6:00.0) set IP 192.168.100.X. Example: sudo ip addr add 192.168.100.2/24 dev enp182s0f0 2. Broadcom CLI – 192.168.100.1 at port 12345...
ECA-4035 User Manual CHAPTER 6: BROADCOM CLI SAMPLE GUIDE The following section aims to guide developers in utilizing the Broadcom Command Line Interface (CLI) for configuring the Broadcom Switch and establishing the necessary environment. Note: The examples below are for reference only, and may not be the same during actual usage.
Page 92
ECA-4035 User Manual 5.1.1.1 BCM_TRUNK_PSC_SRCMAC Spread based on source MAC address. Example: Environmental architecture The client uses the scapy command to send packets to the switch, and then it loads the distribution of traffic across trunk member ports in source MAC address. The example is for reference only.
Page 93
ECA-4035 User Manual 5.1.1.2 BCM_TRUNK_PSC_DSTMAC Spread based on destination MAC address. Example: Environmental architecture The client uses the scapy command to send packets to the switch, and then it loads the distribution of traffic across trunk member ports in destination MAC address. The example is for reference only.
Page 94
ECA-4035 User Manual 5.1.1.3 BCM_TRUNK_PSC_SRCDSTMAC Spread based on source and destination MAC address. Example: Environmental architecture The client uses the scapy command to send packets to the switch, and then it loads the distribution of traffic across trunk member ports in source and destination MAC address. The example is for reference only.
Page 95
ECA-4035 User Manual 5.1.1.4 BCM_TRUNK_PSC_SRCIP Spread based on source IP address. Example: Environmental architecture The client uses the scapy command to send packets to the switch, and then it loads the distribution of traffic across trunk member ports in source IP address. The example is for reference only.
Page 96
ECA-4035 User Manual 5.1.1.5 BCM_TRUNK_PSC_DSTIP Spread based on destination IP address. Example: Environmental architecture The client uses the scapy command to send packets to the switch, and then it loads the distribution of traffic across trunk member ports in destination IP address. The example is for reference only.
Page 97
ECA-4035 User Manual 5.1.1.6 BCM_TRUNK_PSC_SRCDSTIP Spread based on source and destination IP address. Example: Environmental architecture The client uses the scapy command to send packets to the switch, and then it loads the distribution of traffic across trunk member ports in source and destination IP address. The example is for reference only.
Page 98
ECA-4035 User Manual 5.1.1.7 BCM_TRUNK_PSC_ROUND_ROBIN Provides Round Robin Load balancing distribution of traffic across trunk member ports. Example: Environmental architecture The client uses the scapy command to send packets to the switch, and then it loads the distribution of traffic across trunk member ports in Round Robin.
Page 99
ECA-4035 User Manual 5.1.1.8 BCM_TRUNK_PSC_ RANDOMIZED Provides pseudo-random distribution of traffic across trunk member ports. Example: Environmental architecture The client uses the scapy command to send packets to the switch, and then it loads the distribution of traffic across trunk member ports in random. The example is for reference only.
ECA-4035 User Manual 5.3 VLAN 5.3.1 VLAN allocation is based on PVLAN Assign vlan according to the specified ingress port If the received packet is untagged. Example: Environmental architecture CLI Settings: vlan create 3 pbm=xe0,xe20 ubm=xe0,xe20 vlan create 4 pbm=xe1,xe23 ubm=xe1,xe23...
Page 102
ECA-4035 User Manual 5.3.2 VLAN allocation is based on Protocol-based If the received packet is untagged and the ether type and the frame type match a protocol-based VLAN then the VLAN assigned to the packet. Example: Environmental architecture CLI Settings:...
Page 103
ECA-4035 User Manual 5.3.3 VLAN allocation is based on source Subnet (SIP) Add an association from source IP subnet to VLAN to use for assigning a VLAN tag to untagged packets. Example: Environmental architecture CLI Settings: vlan create 3 pbm=xe20...
Page 104
ECA-4035 User Manual 5.3.4 VLAN allocation is based on source MAC address Add an association from source Mac address to VLAN to use for assigning a VLAN tag to untagged packets. Example: Environmental architecture CLI Settings: vlan create 3 pbm=xe20...
ECA-4035 User Manual 5.4 LAYER 3 The Lanner Layer 3 APIs allow application developers to manage the Broadcom L3 switch features, including the L3 fast switching host table, L3 routing table, L3 interface table and L3 ecmp table. L3 packets are routed either based on subnet match, or fast-switched based on a full IP address match.
Page 107
ECA-4035 User Manual PORT MAP Console MGMT Pci bus switch side ethernet name 0000:b6:00.0 XE10 enp182s0f0 0000:b6:00.1 XE11 enp182s0f1 0000:b6:00.2 XE12 enp182s0f2 0000:b6:00.3 XE13 enp182s0f3 Pci bus Front Port ethernet name 0000:02:00.0 MGMT enp2s0 Switch side connected device XE14 Timing Card (1588)
ECA-4035 User Manual APPENDIX A: LED INDICATOR EXPLANATIONS System Power / Status / HDD Activity Green: System Power Red/Green: System Status Amber: HDD Activity COLOR COLOR LED ACTION DESCRIPTION ON LCM ON BOARD Green Green Steady When system power on...
To provide increased flexibility and usage protection, Lanner has released the 2nd Gen Dual BIOS function on Lanner appliances. With 2nd Gen Dual BIOS, both the primary BIOS and secondary BIOS can be updated and flashed using the BIOS Tool to run different versions of BIOS ROMS independently for maximum compatibility.
Page 110
Lanner Technical Support. Warning DO NOT power off or reset the system during BIOS updating process. Disclaimer Under no circumstances will Lanner accept responsibility or liability for damages of any kind whatsoever resulting or arising directly or indirectly from a BIOS update.
ECA-4035 User Manual APPENDIX C: TERMS AND CONDITIONS Warranty Policy 1. All products are under warranty against defects in materials and workmanship for a period of one year from the date of purchase. 2. The buyer will bear the return freight charges for goods returned for repair within the warranty period;...
Page 112
ECA-4035 User Manual RMA Service Request Form When requesting RMA service, please fill out the following form. Without this form enclosed, your RMA cannot be processed.
Need help?
Do you have a question about the ECA-4035 and is the answer not in the manual?
Questions and answers