Installation Read this manual carefully before using the product and keep it in a safe place for reference. This product was constructed up to standard and in compliance with regulations relating to electrical equipment and must be installed by technically qualified personnel. The manufacturer assumes no responsibility for damage to persons or property resulting from failure to observe the regulations contained in this booklet.
• Antimortar cap designed to be used also as template during the installation of the wall support base. • Regenerative heat exchanger with ceramic core (G) with high thermal efficiency, equipped with washable anti-dust filters (H). • External grille (I) made of high quality, impact and UV-resistant ABS, colour RAL 9010, with anti-insect net and water drip guard. •...
Page 4
CONTROLLER ACOUSTIC FUNCTIONALITY DESCRIPTION ICON BUTTON SIGNAL Airflow direction The unit runs in extract/intake at the selected speed: the inversion Alternate time is automatically defined thanks to the integrel temperature sensor green short (comfort mode). Extract The unit runs in extract only at the selected speed. green short Intake The unit runs in intake only at the selected speed. green short Mode (active only if the airflow direction is set on alternate)
BACK UP BUTTON In case the remote controller gets lost or the batteries are dead, ON and OFF position can be selected from the on board touch button (J), pressing the button for at least 3 seconds. LED COLOUR ACOUSTIC SIGNAL green short long...
Page 6
DIMENSIONS (mm) 26,5 300÷560 218 164 q 270÷510 164 q 1 30 External Grille option 2 26,5 218 26,5 ARCHIVIO CAD: \Progetti\..\ External grille External hood External Grille option 1 contenuto imballo modello Quantum NEXT (sostituisce immagine 1 ) contenuto imballo modello Quantum NEXT (sostituisce immagine 1 ) INSTALLATION sostituire possibilmente solo il tubo nell'imm fig.1...
Page 7
outdoor indoor OUTDOOR INDOOR insulation foam INIZIO INSTALLAZIONE aggiungere freccia SOTTOTRACCIA x aprire il coperchietto RECESSED CABLE ENTRY INIZIO INSTALLAZIONE aggiungere freccia SOTTOTRACCIA x aprire il coperchietto H03VV-F ; H05VV-F 2 X 0,5 ÷ 1,5 mm aggiungere freccia x togliere passacavo aggiungere freccia apertura presfondabile x togliere passacavo...
Page 9
115 mm CLICK SURFACE CABLE (for one unit wiring) H03VV-F ; H05VV-F 2 X 0,5 ÷ 1,5 mm INIZIO INSTALLAZIONE SUPERFICIE INIZIO INSTALLAZIONE aggiungere freccia SOTTOTRACCIA x aprire il coperchietto Ø 5 mm INIZIO INSTALLAZIONE aggiungere freccia SOTTOTRACCIA x aprire il coperchietto Ø...
Page 10
aggiungere freccia x inserimento passacavo aggiungere freccia aggiungere freccia x avvitare viti fermacavo x chiudere il coperchietto...
Page 11
115 mm CLICK REMOTE CONTROLLER WALL MOUNTING Ø5mm...
TRMPRO d i s c l o s e d w i t h o u t t h e s p e c i f i c w r i t t e n c o n s e n t o f A e r a u l i q a s r l . A l l r i g h t a r e r e s e r v e d . T h i s d o c u m e n t i s p r o t e c t e d b y p r i v a c y a n d c o p y r i g h t l a w s .
Page 15
MAINTENANCE O F F E DUE LE INSTALLAZIONI) aggiungere frecce x distacco parte ventilante aggiungere frecce x distacco parte ventilante 1 1 5 m m c o l o r a r e f i l t r o colorare filtro e strisce mousse x i n s t a l l p a r t e v e n t i l a n t e colorare filtro e strisce mousse a g g i u n g e r e f r e c c e...
Page 17
MAINTENANCE/CLEANING REGISTER FILTER CLEANING FILTER REPLACEMENT HEAT EXCHANGER CLEANING DATE DATE DATE DATE DATE DATE DATE DATE...
Page 18
ErP Directive - Regulations 1253/2014 - 1254/2014 Mark FANTECH Model AER-60HRV SEC class c1) SEC warm climates kWh/m2.a -18,1 c2) SEC average climates kWh/m2.a -41,7 c3) SEC cold climates kWh/m2.a Energy label Unit typology Residential - bidirectional Type of drive...
Page 19
GOODS AND WARRANTY 1. When supplying goods to a consumer, the following mandated statement applies: “Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage.
Company’s liability Goods or parts that have been returned for repair under this express warranty. (except where the repair is as a result of the Company’s Fantech Contacts Head Office New Zealand Victoria - Melbourne Auckland H.O.
Need help?
Do you have a question about the aerofresh AER-60HRV and is the answer not in the manual?
Questions and answers