Installation guidelines

Keep in mind the following guidelines when installing the domestic
hot water tank:
The installation location is frost-free.
Make sure to make the piping in size 1" or more (and reduce to
3/4" at the inlet of the tank) as to have sufficient water volume in
the piping between unit and domestic hot water tank.
Locate the domestic hot water tank in a suitable position to
facilitate easy maintenance; remember access is required to the
electrical box. Refer to the grey zones in the outlook diagram.
The
domestic
hot
water
EKHWSU150B3V3 can be floor or wall
mounted. In case of wall mounting, wall
mounting kit EKWBSWW150 is required
(separate ordering).
If installing an EKHWSU* domestic hot water tank, installing the
option kit EKUHWB is obligatory. Refer to the UK Building
Regulation G3.
If installing the kit EKSOLHWAV1, installing the option kit
EKUHW2WB is obligatory.
Take care that in the event of a leak, water cannot cause any
damage to the installation space and surroundings

Installing the domestic hot water tank

1
Check if all domestic hot water tank accessories (see
"Accessories" on page 2) are enclosed.
2
When floor mounting, place the domestic hot water tank on a
level surface. When wall mounting (only for EKHWSU150B3V3
model), make sure the wall is sturdy. In both cases, make sure
the tank is mounted level.
3
Apply thermal paste to the thermistor and insert the thermistor as
deep as possible in the thermistor socket. Fix using the nut provided.
EKUHWB + EKUHW2WB + EKHWSU150-300B3V3
Domestic hot water tank with option kit for air to
water heat pump system
4PW44439-1D – 02.2011
tank
model

Connecting the water circuits

Refer to the chapter "Typical application examples" described in the
installation manual delivered with the unit for details on connecting
the water circuits and the motorised 3-way valve.
Connecting the 3-way valve
1
Refer to the figure below before making the connection.
13
77
111
2
Installation position.
It is advised to connect the 3-way valve as close as possible to
the unit. It can be installed in accordance with one of the
following four configurations.
1
2
3
figure A
1
2
3
figure C
AD
1
From
2
To domestic hot water tank
3
To room heating
3
Unpack the 3-way valve body and 3-way valve motor.
Verify that following accessories are provided with the motor.
2
1
1
Sleeve
2
Valve motor cover
3
Screw
4
Scale
38
67
1
3
2
figure B
1
3
2
figure D
unit
4
3
Installation manual