ACCESSORIES
HOSE KIT
Hose kits are available in lengths of 10, 25, and 40 feet. Each hose kit allows for con-
venient installation of the OWC, while allowing for portability within the allowable
space.
NOTICE
—When using these hoses in applications with water pressures exceed-
ing 50 PSIG, a water pressure reducing valve must be installed in the water supply
line prior to the hose kit; otherwise warranty on the hose kits will be void.
All hose kits have FEMALE flare connectors to match the MALE flare fittings on the
units (see chart below). The WATER IN connector consists of a 3/4" garden hose
connection. WATER OUT and DRAIN (condensate) have no fittings, and can be fed
to a sink or permanent drain. When using a hose kit, avoid sharp corners, hot water
pipes and kinking to assure proper water flow of the supply, return, and drain lines.
Hose Kit
Length
HK-1
10 ft
HK-2
25 ft
HK-5
40 ft
HK-3
10 ft
HK-4
25 ft
HK-6
40 ft
Included with the hose kit is a sink/faucet adapter
Flare Conn
OWC12 OWC18 OWC24 OWC36 OWC60
IN-OUT-DRAIN
3/8 3/8 3/8
3/8 3/8 3/8
3/8 3/8 3/8
5/8 5/8 3/8
5/8 5/8 3/8
5/8 5/8 3/8