Rs-232 Control; Configuration - Hall Technologies SW-HD-4A User Manual

4x1 hdmi switch
Table of Contents

Advertisement

RS-232 Control

Configuration

• 115200 baud, No Parity, 1 Stop Bit
• Telnet operation is via port # 6324 of the IP address setting.
• All commands are in ASCII format.
• Commands are NOT case sensitive.
• Each command must be terminated by a single character <CR> (0x0D)
• Unknown commands respond with "INVALID COMMAND"
• All responses are terminated with <CR><LF> (0x0D, 0x0A)
Command
DN
SWn
Where:
n = HDMI Input[1 to 4]
SW?
EMn
Where:
n
Mode
0
Pass-through
1
Static
EM?
EDn
Where:
n
EDID
0
4K2K@60 2 CH
1
4K2K@60 AC3
2
4K2K@60 4:2:0 2 CH
3
4K2K@60 4:2:0 AC3
4
1080P@60 2 CH
5
1080P@60 AC3
6
720P@60 2 CH
7
720P@60 AC3
ED?
Hall Technologies
August 9, 2023
Response
Query Device Name
SW-HD-4A
SWn
Switch to HDMI source
Where:
N = HDMI Input[1 to 4]
SWn
Query switch state
Where:
N = HDMI Input[1 to 4]
EMn
Where:
Set EDID Mode
EMn
Where:
Query EDID Mode
EDn
Where:
Select Static EDID.
NOTE: Static EDID is served to
all the inputs when EDID Mode
is EM1.
EDn
Where:
Query Static EDID Index.
Function
n
Mode
0
Pass-through
1
Static
n
Mode
0
Pass-through
1
Static
n
EDID
0
4K2K@60 2 CH
1
4K2K@60 AC3
2
4K2K@60 4:2:0 2 CH
3
4K2K@60 4:2:0 AC3
4
1080P@60 2 CH
5
1080P@60 AC3
6
720P@60 2 CH
7
720P@60 AC3
n
EDID
0
4K2K@60 2 CH
1
4K2K@60 AC3
2
4K2K@60 4:2:0 2 CH
3
4K2K@60 4:2:0 AC3
4
1080P@60 2 CH
5
1080P@60 AC3
6
720P@60 2 CH
7
720P@60 AC3
Page 8 of 16