S0703-SR (Standard Range) Imager

The depth of field measurements used the following parameters:
Note: Time to Read and Depth of Field are impacted if the barcode symbol is at the edge of
the image.
Guaranteed Specs
Focus
Symbology
5 mils Code 39
10 mils Code 39
20 mils Code 39
13 mils 100% UPC-A
15 mils Code 128
10 mils Data Matrix
CT30 XP Mobile Computer Series User Guide
Default
Enable
Disable
Disable
Disable
Disable
Enabled
Enabled
Enabled
Distances are measured from the front of the Imager.
+23°C (+73°F), 0 lux for guaranteed, 200 lux for typical.
Photographic quality codes
2D Symbologies
Digimarc
TLC 39
Standard Range
Near Distance
mm
in.
mm
in.
mm
in.
mm
in.
mm
in.
mm
in.
Postal Codes
Default
Disabled
Disabled
Change the Scanner Settings
Far Distance
79
270
3.11
10.63
40
425
1.57
16.73
44
674
1.73
26.53
44
493
1.73
19.41
42
572
1.65
22.52
83.1
236
3.27
9.29
Default
on