Wiring - QuietCool GA ES-1500 Owner's Manual

Hide thumbs Also See for GA ES-1500:
Table of Contents

Advertisement

3. WIRING

IMPORTANT:
!
!
electrician following local building and electrical codes and/or NEC guidelines.
NOTE:
Your fan may have come with the RF Hub or Thermostat pre-wired to a power cord for
! !
testing purposes before installation. The power cord can be used when installed inside of an attic.
DO NOT USE THE POWER CORD OUTDOORS. If you would like to hard-wire the fan, or it is
required by your local building codes, please follow the wiring instructions below.
3.1
GA ES-1500 WIRING WITH RF CONTROL
1. Using a wire nut, connect the black wire from the power source to the black wire from the Hub.
2. Connect the white wire from the power source and the white wire on the fan to the white wire
from the Hub.
3. Cap the red wire on the Hub.
4. Cap the yellow wire on the Hub.
5. Connect the black wire from the fan to the blue wire on the Hub.
6. Ground the green wire from the fan and the ground wire from the power source to the ground
screw in the Hub.
7. Set the dip switch positions inside the Hub as shown in the diagram.
8. Power-on the Hub. The Power LED indicator will be lit.
9. Press the Test button to make sure the fan works. The Test LED indicator will blink three times
every two seconds indicating 1-speed and the fan will be on. Press the Test button again and the fan
should shut off and the LED will be off.
10. If the fan doesn't operate as described in step 9, please check the dip switch postion.
11. You can connect up to 20 switches to a single hub.
8
Wiring Diagrams are for examples ONLY. Wiring should be done by a licensed