G-5500 Antenna Azimuth-Elevation Rotators & Contoroller Instruction Manual
IF the optional GS-232 Computer Control Interfaces Unit is installed, the RS-232C cable from the
computer routes through this grommet, and is affixed in place by the nylon cable clamp.
P i n
Function
6
Provides 2 to 4.5VDC corresponding to 0 to 450°
1
Provides 2 to 4.5VDC corresponding to 0 to 180°
4
Connect to Pin 8 to rotate left (counterclockwise)
2
Connect to Pin 8 to rotate right (clockwise)
5
Connect to Pin 8 to rotate UP
3
Connect to Pin 8 to rotate DOWN
7
Provides DC13V to 6V at up to 200mA
8
Common ground