Error Codes - A.O. Smith 910 ASME Troubleshooting Manual

On-demand water heater
Hide thumbs Also See for 910 ASME:
Table of Contents

Advertisement

 
5.3 TROUBLESHOOTING ‐ ERROR CODES 
All tankless units are self diagnostic for safety and convenience when trouble shooting. 
If there is a problem with the installation or the unit, it will display a numerical error code on 
the  Remote  Controller  (if  installed),  or  on  the  7‐Seg  LED  on  the  computer  board  to 
communicate the source of the problem.  
The  910  (T‐M50)  is  two  units  combined  into  one  case.    See  the  diagram  below  to  determine 
whether the problem is in the left or right side of the 910 (T‐M50). 
Consult the following chart for the cause of each error code. 
 
 
 
 
 
 
 
 
 
 
Figure 4 – Error Code Location 
 
 
Table 2 – Error Codes 
 
Error Code  
 
031 
 
101 
 
111 
 
121 
 
311 
 
321 
 
 
331 
 
391 
 
441 
510 
 
551 
611 
631 
651 
661 
681 
701 
721 
741 
 
761 
 
991 
 
7-Seg LED
Malfunction Description 
Incorrect Dipswitch Settings 
Warning for 991 Error Code 
Ignition Failure 
Output Thermistor 
Inlet Thermistor 
Mixing Thermistor 
Air‐fuel Ratio Rod Failure 
Flow Sensor (Easy‐Link, Multi‐Unit System only) 
Abnormal Main Gas Valve 
Abnormal Solenoid Gas Valve 
Abnormal Fan Motor 
Flow Adjustment Valve ( Easy‐Link, Multi‐Unit System only) 
Bypass Valve Fault 
External Fan Motor Failure 
Computer Board Fault 
False Flame Detection 
Remote Controller Communication Failure 
Communication Failure    (Easy‐Link, Multi‐Unit System only) 
Abnormal combustion 
12|
Page 
 
The top red lamp will
flash when the right
combustion section has
an error code.
The mid red lamp will
flash when the left
combustion section has
an error code.
Flame Loss 
Pump Failure 
Troubleshooting Guide 
Figure 5 – TM‐RE30 
Remote Controller

Advertisement

Table of Contents
loading

This manual is also suitable for:

910T-m50T-m50 asme

Table of Contents