CM-MD64 MADI Bridge Hardware Overview: Front Panel Front Panel Connecting the Hardware MegaCOMMS System Connection Options Setting up the CM-MD64 for a MADI Network Front Panel Dip Switch Settings Important Notes Appendix A: Example System Configurations System 1 System 2...
Important Safety Information CAUTION: These servicing instructions are for use by qualified personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the User Manual unless you are qualified to do so. Refer all servicing to qualified service personnel. 1.
General Precautions • Do not place heavy objects on the Network Bridge, expose it to sharp objects or handle the unit in any way that may cause damage, e.g., rough handling and /or excessive vibration. • Do not subject the equipment to dirt, dust, heat or vibration during operation or storage. Never expose the Network Bridge to rain or moisture in any form.
Declaration of Conformity The following pages show the individual declarations of conformity, for both the CE and UKCA marks, for the Cadac CM-MD64 MADI audio network bridge. CM-MD64_24-05-2023_Iss-1.docx Page. 6 / 31...
Page 7
We, SCC Audio Limited, of 1 New Street, Luton, Bedfordshire, LU1 5DX declare under our of Conformity (DoC) sole responsibility that the Cadac CM-MD64 MADI bridge, as detailed below complies with CM-SR Series the provisions of the following UKCA Directives and is eligible to bear the UKCA mark:...
Page 8
We, SCC Audio Limited, of 1 New Street, Luton, Bedfordshire, LU1 5DX declare under our (DoC) sole responsibility that the Cadac CM-MD64 MADI bridge, as detailed below complies with CM-SR Series the provisions of the following European Directives and is eligible to bear the CE mark:...
“high-agility” user interface utilising a wide format touch screen. Professional sound engineers familiar with other digital consoles will find the transition to the Cadac workflow quick and intuitive.
Overview The Cadac CM-MD64 unit is used as part of a larger audio system made up of multiple units: digital mixing console(s) and remote MegaCOMMS I/O device(s). The CM-MD64 is an audio network bridge enabling MADI units to be incorporated within Cadac’s MegaCOMMS audio network.
Rear Panel The only connections that are not on the front panel are the power connections for the dual internal, auto switching, power supplies. The connectors accept the standard and locking IEC cables. 1. PSU connectors: The dual internal PSUs have an input range of 100-240 V AC~50-60Hz, the output requirements are +17 V, -17 V, +12 V, with a front mounted power switch.
MADI Bridge Overview The Cadac CM-MD64 is a 1U, MADI to MegaCOMMS audio network bridge, enabling MADI units to be incorporated within a MegaCOMMS audio network. The unit supports up to 64 bi-directional connections to map between MegaCOMMS ports and a MADI network.
MegaCOMMS: Data Protocol Communication between the unit and the console is via a proprietary Cadac high speed protocol called MegaCOMMS. The protocol uses high-speed 75 ohm coaxial cable terminated in BNC connectors or depending on the unit, via fibre optic cable using the duplex optical LC ports.
• Set to ‘2’ when connecting the CM-MD64 to a console, and it is to be used as RACK 1 • Set to ‘3’ when connecting the CM-MD64 to a console, and it is to be used as RACK 2...
Page 16
Word Clock set by a third-party unit within MADI network that is connected to the MADI Ports [2]. If both LEDS are OFF, the CM-MD64 is acting as the Word Clock for the network. 9. Word Clock IN / Word Clock OUT: Word Clock IN or OUT - on BNC connectors for 75 ohm co-axial cable - to ensure the synchronisation of the digital signal with the network.
CM-MD64 will automatically switch its comms to Path B if communication is lost on Path A, such as might occur if a cable is damaged. Note that the CM-MD64 is fully functional in all respects if only one coax TX / RX or optical path is connected.
Coaxial Cable Run ≤ 100m Cadac CM-J series SR series stage rack CM-MD64 Coaxial Cable Run ≤ 100m NOTE: With the system setup above MegaCOMMS PORT A on the CM-MD64 and stage rack MUST be connected to the console. CM-MD64_24-05-2023_Iss-1.docx Page. 18 / 31...
Page 19
Coaxial Cable Run ≤ 100m CM-MD64 NOTE: With the system setup above MegaCOMMS PORT A on the CM-MD64 and stage rack MUST be connected to the console. Console and CM-MD64: Redundant System System below using one CM-MD64 using coaxial cables only...
Page 20
Cable Run ≤100m CM-MD64 NOTE: With the system setup above MegaCOMMS PORT A on the CM-MD64 and stage rack MUST be connected to the console. The coaxial cables linking the console to the racks must be of similar length. System below using one CM-MD64 and CM-SR stage rack with the CM-SR using fibre optic cable Fibre Optic Cable Run ≤...
Page 21
CM-MD64 NOTE: With the system setup above MegaCOMMS PORT A on the first stage rack MUST be connected to the console. System below using one CM-MD64 and CM-SR stage rack with the CM-SR using fibre optic cable CM-MD64 Cadac CM-J...
Setting up the CM-MD64 for a MADI Network The following section provides a guide on how to set up the Cadac CM-MD64. Front Panel Dip Switch Settings The table below shows how the unit can be configured via from Configuration DIP switch [3] on the front...
Appendix A: Example System Configurations This section shows 4 example configurations using the CM-MD64 to integrate a Third Party MADI unit - which is running at either 48 kHz or 96 kHz - into a MegaCOMMS network. System 1 Cadac Console and Stage Rack running 64 bi-directional channel 48 kHz MADI stream to a Third Party...
Page 24
System 2 Cadac Console and Stage Rack running two 32 bi-directional channel 96 kHz MADI streams to a Third Party MADI unit via the CM-MD64. The system is also running a second pair of MegaCOMMS to the CM-MD64 as a back-up:...
System 3 Cadac Console running one 64 bi-directional channel 48 kHz MADI stream to a Third Party MADI unit via the CM-MD64: Cadac CM-MD64 MegaCOMMS Ports Channels 1- 64 at 48 kHz bi-direction MegaCOMMS Ports Cadac console Third Party MADI unit...
When the FPGA Has Been Programmed • Power cycle the CM-MD64 Power off - wait 5 seconds - power on • Wait 8-10 seconds and LEDs should illuminate on the front of the unit • CM-MD64 is now fully programmed CM-MD64_24-05-2023_Iss-1.docx...
Operates up to 500m over optical fibre li nk and 200m coaxial copper link Optical transmission on SC Duplex connectors Cooper transmission on 75 ohm coaxial BNC connectors MegaCOMMS 2 x Cadac MegaCOMMS on: • 4 x BNC connectors Audio S pecification Sample Rate...
Page 31
One New Street whether mechanical or electronic, without the Luton written permission of Cadac. Bedfordshire Due to Cadac’s policy of continual improvement Cadac reserves the right to England alter features, appearance and specifications LU1 5DX without notice.