Make the slit part of heat insulator to upward.
Insulate the indoor unit completely so there are no gaps using the heat insulator provided.
Securely apply insulation all the way up to the pipe connecting section of the indoor unit so that there
When wrapping the heat insulator around pipes, make sure the slit aperture toward the ceiling surface.
• Carefully arrange pipes so that any pipe does not stick out of the rear plate of the indoor unit.
the vinyl tape, etc.
• Since dew results in a machine trouble, make sure to insulate both the connecting pipes.
(Use polyethylene foam as insulating material.)
• When bending a pipe, carefully do it, not to crush it.
11-EN
Gas side
10
Liquid side
Cut the heat insulator of the gas pipe
(locally procured) leaving a 10 mm
overlap with the shield of the shield pipe.
Installation plate
Heat insulator provided
A
A
Indoor unit shield pipe
CAUTION
CAUTION
Indoor unit
Power supply wiring
Control wiring
– 11 –