20
HP L2335
Go to cover page
Step 2: Read DDC data from monitor
1.
Click
icon as shown in Fig. 12 from the tool bar to bring up
the Channels "Configuration Setup" windows as shown in Fig. 10.
2. Select the DDC2Bi as the communication channel.
As shown in Fig. 10.
Fig. 10
3. Click OK button to confirm your selection.
4. Click
icon (Read EDID function) to read DDC EDID data from
monitor. The EDID codes will display on screen as shown in Fig. 11.
Modify DDC data (Serial No.)
1.
Click
icon on the tool bar.
2.
Click
till the Step 9 of 9 window appears.
3.
Type the new Serial No. (for example, TWP335Z001).
4.
Click
till the last step window appears, then click
exit the Step window.
Write DDC data to monitor
1. Click
icon from the tools bar to starting rewrite DDC data.
2. Click
for confirmation.
3. In order to match the same serial number in OSD with DDC data,
The following action should be executed.
*****************************************************************************
Change/update the serial number which should be proceeded
by application software "SerialNumber.exe" as shown in Fig. 12
*****************************************************************************
*****************************************************************************
Connection :Using IIC & Rs232 Alignment Kits(3138 106 10198)
for Serial Number applicationFig.13.
*****************************************************************************
PC
Monitor (A)
25 pins 9 pins
Connect to
Mains cord
Video cable
DDC Instructions
Fig. 12
Monitor (B)
Com1 or
Rear view of HP L2335
Com2
9 pins
Fig. 13
Attention :
Before doing "SerialNumber.exe" in your windows 98 PC, The HPL2335 monitor
must be in the factory mode, then run following process as below.
Step 1: Double click "SerialNumber.exe"
Bring up: Fig. 14
Fill out serial number of monitor.
For example "TWP335Z001" as shown in Fig. 15.
to
Fig. 15
Fig. 11
Step 2: Click "Serial Number" as shown in Fig. 16.
Fig. 16
Bring up Fig. 16 with "57600,n,8,1 Com1"
Step 3: Verify "Serial Number" by OSD as shown in Fig. 17.
Press OK button
=>select "management"
=>press OK Button,then
=>select "Serial Number"
=>press OK Button
Bring up :
Fig. 17 for verification.
Fig. 17
Fig. 14
(click "Serial Number")
(Com port for application)
TWP335Z001

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ij6b2w/02Ij6b2w/33Ij6b2w/69

Table of Contents