LED EPI-FLUORESCENSE MICROSCOPE CODE HBF002 INSTRUCTION MANUAL Note: This manual provides instructions for both mercury lamp and LED epi-fluorescense microscopes Version 1, september 2019 Instruction Manual HBF002...
Packing Waste Disposal For the protection of the environment, please properly handle the microscope packing waste or send to salvage station (such as cardboard, foam, etc. ) Version 1, september 2019 Instruction Manual HBF002...
Epi-excitation principle and provided with 4 group excitation filters system of FL4: blue (B), green (G), violet (V) and ultraviolet (UV). Auramine is optional used for tuberculosis 455mm. B curve of spectrum G curve of spectrum V curve of spectrum Uv curve of spectrum Version 1, september 2019 Instruction Manual HBF002...
F20. LED power box F6. Lamp box locking screw F12. Mercury lamp power box F21. Output socket for power F7. Fluorescence mercury F13. Power input socket lamp box F14. Output interface F22. Power connecting wire Version 1, september 2019 Instruction Manual HBF002...
1.2.9. Insert external power source plug in F13 power socket. Installation finished.(Fig. 1-5) ▲ Please carefully check whether power supply voltage is in conformity with input voltage. Switch on the power. Fig. 1-5 Version 1, september 2019 Instruction Manual HBF002...
Fig.1-10 1.4.5. Adjusting field diaphragm lever F25 to the maximum open scale(if necessary, adjusting the field diaphragm centering handle F24 to diaphragm and field in the same center.(Fig .1-11) Fig.1-11 Version 1, september 2019 Instruction Manual HBF002...
Page 9
3 minutes. ▲ Fluorescence microphotograph requires a long exposure time, so the fluorescence digital photography device is the best choice. Version 1, september 2019 Instruction Manual HBF002...
2.2.4. Please attention prevent microscope from violent shake and vibration in application and in carrying. Don’t drag it on the surface of worktable to avoid damage to microscope and worktable. Version 1, september 2019 Instruction Manual HBF002...
2.4 Storage 2.4.1 When not in use, must turn off power and placed in a cool, dry environment with dust-cover. 2.4.2 Eyepiece and objective should be placed in dry container with desiccant. Version 1, september 2019 Instruction Manual HBF002...
Left and right eyepiece is different. Replace same eyepieces. Interpupillary distance isn’t adjusted Adjust Interpupillary distance. correctly. It is easy for eyes to be Diopter isn’t adjusted correctly. Adjust diopter tired during observing. Brightness isn’t enough Adjust brightness Version 1, september 2019 Instruction Manual HBF002...
Diaphragm directions, hollow circle is turn up, solid is turn down. Field Diaphragm Aperture Diaphragm Optical Shutter Pass 0 Optical Shutter Pass 50% Optical Shutter Pass 100% Switch Directions , an enhanced thickness means heavy. Recycle Mark Version 1, september 2019 Instruction Manual HBF002...