Zuzi 158 Series Operation Manual

Research biological microscope

Advertisement

Available languages

Available languages

Quick Links

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
M A N U A L D E U S O
 
 
 
 
 
Microscopio profesional
 
 
 
 
 
 
Serie 158
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Lea detalladamente este manual de intrucciones con el fin de
obtener las máximas prestaciones del equipo.

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 158 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Zuzi 158 Series

  • Page 1                               M A N U A L D E U S O           Microscopio profesional             Serie 158  ...
  • Page 2: Table Of Contents

                Prólogo ........................…….1   Ⅰ E s pecificacione s ....................…….2 Ⅱ Configuración …………..................……..3 Ⅲ Instalación ......................…….7 Ⅳ Instrucciones de uso ................……….8   1. Ajuste iluminación ................……….8 2. Colocación muestra ..................…….8 3. Enfoque …………..................………8 4.
  • Page 3: Prólogo

    Prólogo   Serie 158   Microscopio biológico de investigación     Las características de este microscopio, lo convierten en un equipo excepcional no solo por las prestaciones sino también por sus aplicaciones. Su diseño modular se adapta a las necesidades más exigentes y su alta ergonomía permite largos periodos de trabajo sin fatiga.
  • Page 4: Ⅰ Especificaciones

    Ⅰ Especificaciones         Sistema óptico Corregido a infinito     Cabezal binocular compensación libre, Inclinación ajus ~ table 0º-40º     Cabezal triocular compensación libre, Inclinación ajusta~ b le 0º-40º Cabezal   Separador de haces: Oculares 50%, tubo triocular 50%  ...
  • Page 5: Ⅱ Configuración

      Ⅱ Configuración —158/7       Oculares       Cabezal binocular                   Tornillo sujeción cabezal             Revólver       Objetivos       Platina mecánica  ...
  • Page 6   —158/7                                             Sujeción compart. lámpara         Comp. lámpara       Palanca diafragma apertura    ...
  • Page 7       Ocular     Cabezal triocular               Tornillo sujeción cabezal         Revólver         Objetivos       Platina mecánica Mando ajuste filamento arriba-abajo        ...
  • Page 8 158/8                                             Sujeción compart. lámpara       Comp. lámpara         Palanca diafragma apertura     Lente deslizante  ...
  • Page 9: Ⅲ Instalación

    Ⅲ Instalación                                                                              ...
  • Page 10: Ⅳ Instrucciones De Uso

      Ⅳ Instrucciones de uso       1. Ajuste intensidad iluminación Fig. 6 .         1)Pulse el interruptor general ① a posición “I”           2)Gire el mando de intensidad ② en el sentido de la  ...
  • Page 11     ○ Ajuste de tensión del mando macrométrico (Fig. 9. )     1) La tensión del mando macro es ajustable. Ajuste el anillo ① en sentido de la flecha para aumentar la tensión y en sentido contrario para disminuirla  ...
  • Page 12: Ajuste Dioptrías

    6. Ajuste de dioptrías (Fig. 12) .   ◎ Ajuste la visión de los ojos derecho e izquierdo ○ 1)En primer lugar, observando con el ojo derecho, gire los mandos macro y micro hasta conseguir una clara imagen de la muestra 2)A continuación, observando con el ojo izquierdo, gire el anillo de dioptrías ①...
  • Page 13: Cambio Objetivos

    9. Ajuste del diafragma de campo ( Fig. 1) 6 .   Ajuste el diafragma de campo para hacer coincidir el área de iluminación con el campo del ocular. Si el diafragma de campo es mayor que la apertura requerida, la luz externa entrará...
  • Page 14: Ajuste Fuente De Luz

    12. Ajuste de la fuente de luz ( Fig. 19 ) .   Ajuste la posición del filamento para conseguir una mejor iluminación ○ 1)Mando de ajuste del filamento adelante-atrás ① 2)Mando de ajuste del filamente arriba-abajo ② ○ 3)Mando de ajuste del filamente derecha-izquierda ③  ...
  • Page 15 14. Conexión del cable de corriente ( Fig. 21. Fig. 22. & Fig. 23 ) .           1)Pulse el interruptor ① a la posición “O” (OFF) y tconecte el cable de corriente 2)Inserte el enchufe ② en la clavija ③, y asegúrese de que la conexión es buena.
  • Page 16: Ⅴ Resolución De Problemas

    Ⅴ Resolución de problemas   Dependiendo del modo de uso, aunque no sea debido a un malfuncionamiento, el rendimiento del equipo puede no ser completo. Si ocurre un problema, intente localizar la causa.   Problema Causa Solución pág.   El objetivo no está en el paso de luz Asegúrese que el objetivo está...
  • Page 17 Operation Manual Research Biological Microscope Series 158 In order to exert performance of this microscope completely, please read Operation Manual carefully before use and make it well-kept after use.
  • Page 18 Directory Prologue ........................…….1 Ⅰ Specification .......................…….2 Ⅱ Configuration …………..................……..3 Ⅲ Installation ......................…….7 Ⅳ Detailed observation steps ................……….8 1. Brightness adjustment ................……….8 2. Specimen emplacing ..................…….8 3. Focusing …………..................………8 4. Drawtube adjustment ..................……..9 5. Interpupillary distance adjustment ..............……..9 6. Diopter adjustment ..................……10 7.
  • Page 19: Prologue

    Prologue Series 158 Research Biological Microscope The diversification of this model brings you enter into an epoch not only the performance, but also the application. The module design can meet your needs on all normal experiment and scientific research. Its humanized configuration design, reasonable control device and layout of every operation knob can keep your eyes, neck, shoulders, waist, arms and wrist against tiredness.
  • Page 20: Ⅰ Specification

    Ⅰ Specification Optical system Corrected Infinite optical system Compensation free binocular head, Incline adjustment 0 ~40 Compensation free trinocular head, Incline adjustment 0 Viewing head ~40 Beamsplitter rate: Binocular head 50%, Trinocular head 50% Interpupillary distance 55mm~75mm Eyepiece WF10×/22mm × () Nosepiece Quintuple nosepiece (...
  • Page 21: Ⅱ Configuration

    Ⅱ Configuration —158/7 Eyepiece Humanized binocular head Head locking screw Nosepiece Objectiv Mechanical stage Filament up & down adjusting knob Centering screw of Condenser Light Collector Filament left & right adjusting knob Main body Light source collecting lens focusing knob Light adjusting knob Condenser locking screw Base...
  • Page 22 —158/7 Fixing screw of lamp housing Lamp housing The rod of condenser diaphragm Swing type condenser Adjusting ring of light collector diaphragm Lock screw of lamp housing cover Condenser up & down adjusting knob adjusting knob Fine focusing knob Tension adjusting ring Coarse focusing knob Fig 2.
  • Page 23 Eyepiece Humanized trinocular head Head locking screw Nosepiece Objective Mechanical stage Filament up & down adjusting knob Centering screw of Condenser Light collector Main body Filament left & right adjusting knob Light source collecting lens focusing knob Base Condenser fixing screw Power switch Light adjusting knob Transversal movement adjusting knob...
  • Page 24 158/8 Fixing screw of lamp housing Lamp housing The rod of condenser diaphragm Swing type condenser Condenser up & down adjusting knob Lock screw of lamp housing cover Adjusting ring of light collector diaphragm Coarse focusing knob Tension adjusting ring Fine focusing knob Fig.
  • Page 25: Ⅲ Installation

    Ⅲ Installation Fig. 5. Objective Swing type condenser Base Lamp housing Power source cable Humanized binocular head Eyepiece...
  • Page 26: Ⅳ Detailed Observation Steps

    Ⅳ Detailed Observation steps 1. Brightness adjustment(Fig. 6.) “I” 1)Press main power switch ① to side. 2)Revolving brightness knob ② as per arrowhead to brighten and darkle rightabout. The arrowhead ○ on the switch panel shows voltage value. ○ Fig. 6. 2.
  • Page 27: Drawtube Adjustment

    Adjusting tension of coarse focusing ○ knob(Fig. 9.) 1)Tension of coarse focusing knob is adjustable. Adjusting the ring ①as per arrowhead direction to make heavy tension and reverse way to make light tension 2) If you find the mechanical stage slides down ○...
  • Page 28: Diopter Adjustment

    6. Diopter adjustment(Fig. 12.) ◎ Adjust eyesight of left & right eye of observer ○ 1)Firstly observe right side eyepiece by right eye, rotating coarse & find focusing knob till you see clear image of specimen 2)Then observe left side eyepiece by left eye, rotating Diopter ring ①...
  • Page 29: Field Diaphragm Adjustment

    9. Field diaphragm adjustment(Fig. 16.) Adjusting Field diaphragm ring to make illumination area fitted with eyepiece field. If the Field diaphragm is bigger than aperture required, external light will come into the viewing field, that will interfere the quality of image and the contrast Fig.
  • Page 30: Light Source Adjustment

    12. Light source adjustment(Fig. 19.) Adjusting position of filament to obtain better illumination ○ 1)Filament forward or backward adjusting knob ① 2)Filament up or down adjusting knob ② ○ 3)Filament left or right adjusting knob ③ ○ Fig. 19. 13. Changing the bulb(Fig. 20.) ★...
  • Page 31: Connecting Power Cable

    14. Connecting power cable(Fig. 21. Fig. 22. & Fig. 23.) 1)Turn the power switch ① to “O” (OFF), then connect the power cable. 2)Insert the plug ② into the inlet ③, and make sure the connection is good. ○ 3)Insert another end plug ④ of the power wire to the power supply socket ⑤...
  • Page 32: Ⅴ Problems Occurred In Using And Disposal Method

    Ⅴ Problems occurred in using and disposal method According to different use method, although it is not malfunction, the microscope performance may not be given out completely. If the trouble occurred, please try to find the cause. Problem point Cause Disposal method page Objective is not entered into the light path...