CLEANUP

1.
Switch the unit off.
2.
Hold the paint spray gun in the original container. Press the
trigger to release the pressure in the spray gun container.
3.
Undo the paint container closing lever and remove the container.
4.
Empty the remaining coating material into the original container.
5.
Fill the spray gun container with solvent or water and fit onto the
spray gun.
Only use solvents with a flash point above 100˚F
(38 °C).
6.
Shake the paint spray gun well.
7.
Switch the unit on and spray the solvent or water into an open
container.
Never spray into a container with only a small
opening (bunghole)!
8.
Repeat this procedure until the solvent or water coming out of
the tip is clear.
Then empty the paint container completely.
Never leave solvents in the spray gun container;
this may cause pressure to build up in the container.
Always keep the paint container seal clean of left over coating
material and check regularly for signs of damage.
9.
Switch the unit off.
10.
Clean the outer surfaces of the paint container and paint spray
gun with a cloth soaked in solvent or water.
Do not leave the Maxum III spray gun immersed
i
in solvent or water for extended periods! (The
seals and air pipe on non-return valve may swell,
preventing them from functioning properly.)
11.
Unscrew adjusting ring, remove air cap and spring plate. Unscrew
nozzle. Clean air cap, tip and needle with brush and solvent or
water.
Never use sharp metal objects to clean the nozzles
i
or air channels of the Maxum III spray gun.
12.
Apply a fine coat of silicone-free oil to the marked areas (fig 18).
13.
If the paint spray gun is not used for any length of time, it should
be cleaned and protected by applying a fine coat of silicone-free
oil.
CLEANUP