HEN THE AIR CONDITIONER IS NOT
GOING TO BE USED FOR A LONG TIME
1
Operate by COOL mode with the highest temperature
set or FAN mode for 3 to 4 hours.
• This dries the inside of the unit.
• Moisture in the air conditioner contributes to favorable conditions for
growth of fungi, such as mold.
2
Press
to stop the operation.
3
Turn off the breaker and/or disconnect the power sup-
ply plug.
4
Remove all batteries from the remote controller.
When using the air conditioner again:
1
Clean the air filter.
Page 12
2
Check that the air inlet and outlet of the indoor and
outdoor units are not blocked.
3
Check that the earth is connected correctly.
4
Refer to the "PREPARATION BEFORE OPERATION",
and follow the instructions.
Page 6
Page 5
I
NSTALLATION PLACE AND
ELECTRICAL WORK
Installation place
Avoid installing the air conditioner in the following places.
• Where there is much machine oil.
• Salty places such as the seaside.
• Where sulfide gas is generated such as hot spring, sewage, waste water.
• Where oil is splashed or where the area is filled with oily smoke (such as cook-
ing areas and factories, in which the properties of plastic could be changed
and damaged).
• Where there is high-frequency or wireless equipment.
• Where the air from the outdoor unit air outlet is blocked.
• Where the operation sound or air from the outdoor unit bothers the house next
door.
• The mounting height of indoor unit 1.8 m to 2.3 m is recommended. If it is
impossible, please consult your dealer.
• Do not operate the air conditioner during interior construction and finishing
work, or while waxing the floor. Before operating the air conditioner, ventilate
the room well after such work is performed. Otherwise, it may cause volatile
elements to adhere inside the air conditioner, resulting in water leakage or
scattering of dew.
• This equipment should be installed and operated with a minimum distance of
20 cm between the device and the user or bystanders.
Inverter-type
fluorescent lamp
To prevent the effects
of a fluorescent lamp,
keep as far apart as
possible.
Keep a space
to prevent
the picture
distortion or
1 m
the noise.
or more
1 m
or
Cordless
TV
more
phone or
Portable
phone
Radio
3 m or more
Electrical work
• Provide an exclusive circuit for the power supply of the air conditioner.
• Be sure to observe the breaker capacity.
If you have any questions, consult your dealer.
S
PECIFICATIONS
Guaranteed operating range
Indoor
32°C DB
Upper limit
23°C WB
Cooling
21°C DB
Lower limit
15°C WB
The installation location of the outdoor
unit should be at least 3 m away from
the antennas for TV sets, radios, etc. In
areas where the reception is weak, pro-
vide greater space between the outdoor
unit and the antenna of the affected
device if operation of the air conditioner
interferes with radio or TV reception.
For the optimum ef-
ficiency and to extend
wall, etc.
the life time of using,
the outdoor unit
should be installed in
a well-ventilated dry
place.
100 mm or
more
500 mm or more
Outdoor
46°C DB
-10°C DB
DB : Dry Bulb
WB : Wet Bulb
En-14