Download Print this page

GE JV555 Owner's Manual And Installation Instructions page 12

Advertisement

Installation
Instructions
[] REMOVE
DUCT KNOCKOUT(S)
If recirctdath_g,
non-vented
ductless
(Ol_tional for
,IV5 Series models
only), see uote below and skip to
Step 12 D and proceed.
We do not recommend
the
recirculated
configuration
for JV6 Series models.
Using a fiat blade
screwdriver;
remove
the ai_i_ropriate
duct lmockout(s)
fi'om the top or back of the hood.
3'/4"x I0" Rectangular
vertical discharge•
Remove top rectangular
duct knockoutonly.
7" Roundvertical
discharge, Remove semi-
circularduct knockout a ndtop
rectangularduct knockout.
3'/4" x 10" Rectangular
horizontal discharge• Remove
rear rectangular duct knockout only.
NOTE:
If the hood
is to be installed
in a recirculating,
non-vented
ductless
manne_;
order
charcoal
filters,
kit nmnber
WB02X10707
fin" 30" hood
models
or
kit ntlillbeF
WB02X10708
fin" 36" hood
models.
These
kits can be ordered
ti'om yore" GE sui_plie_:
Skip to Step 12 D mid proceed.
[] FOR HORIZONTAL
DISCHARGE
INSTALLATIONS
ONLY:
Remove
the plate
(on models
so equiI)ped
) in fl'ont
of the horizontal
discharge
knockout.
Cut the ties,
lift plate
out and
discard
plate.
DO NOT REMOVE
the metaJ strip held in place with two screws.
Metal strip
Ties
Screw
[]
FOR 31/4 " X 10" RECTANGULAR
DUCTED DISCHARGE
INSTALLATIONS
ONLY:
Mtach
exhaust
adaptor/da_aper
over knockout
opening
with two exhaust
adaptor
screws. Make sure
damper
pivot is nearest
to top/back
edge
of hood.
Remove
tape ti'om damper
flap.
Upto 1" side-to-
Tape
sideadjustment
Pivot
Exhaust a daptor/damper
(verticaldischargeposition
shown)
NOTE:
The
exhaust
adai)tor/damper
can
be installed
up to 1 inch
on
either
side
of the
hood
center
to
aCCOlillilo(late
off=center
ductwork.
]n extreme
off =
center
installations,
one
end
of the
duct
connector
may
need
to be trimmed
to clear
the
electrical
cable
clamp.
[]
FOR 7" ROUND VERTICAL
DUCTED DISCHARGE
INSTALLATIONS
ONLY:
Re-install
the 7" round
exhaust
adaptor
with its
screws, removed
in Step 2 trader
the "Prepare
the
Hood"
section.
NOTE:
The 7" rotmd
exhaust
adaptor
can be installed
up to 1 inch on either
side of the hood
center
to
aCCOllllllodate
oItcenter
dtlctwork.
In
exti'ellle
oItLcenter
instnllations,
one end
of the duct connector
may need
to be trimmed
to clear the electrical
cable clamp.
NOTE:
The 7" r(mnd
damper
is not included
with
this i_roduct.
It can be i_m'chased
as a kit b) calling
800.626.2002.
Order
kit nmnber,]'X[
A2..
12

Advertisement

loading

This manual is also suitable for:

Jv536Jv565Jv566Jv655Jv636Jv665 ... Show all