6.
using a 10 mm spanner, unscrew
the hinge pin (E) and reassemble it
on the opposite side of the hinge;
7.
reassemble the lower hinge (E) on
the opposite side, using the screws
previously removed. Slide the hole
cover (F) out of the ventilation
grille (D) by pushing it in the
direction of the arrow and
reassemble it on the opposite side;
8.
refit the ventilation grille (D), clip-
ping it into place;
9.
Unscrew the handle. Refit it on
opposite side after having pierced
the plugs with a punch. Cover the
holes left open with the plugs con-
tained in the documentation pack.
Attention:
After having reversed the ope-
ning direction of the doors check
that all the screws are
properly tightened and that the magnetic seal adheres to the cabinet. If the
ambient temperature is cold (i.e. in Winter), the gasket may not fit perfec-
tly to the cabinet. in that case, wait for the natural fitting of the gasket or
accelerate this process by heating up the part involved with a normal hair-
drier.

Electrical connection

Before initial start-up, refer to the appliance rating plate to ascertain if sup-
ply voltage and current values correspond with those of the mains at the
installation location.
e.g.:
(i.e. 230 to 240 volts alternating current, 50 Hertz)
The rating plate is inside the appliance on the left.
A correctly installed, earthed socket is required for the electrical supply. The
supply must have a fuse rating of at least 10 Amps.
62
AC
230 ... 240 V
230 ... 240 V~
50 Hz
50 Hz or
G