COSMETIC INSPECTION AFTER REPLACEMENT OF
DOCK FRAME AND/OR THE END CAPS
9. Dock to Grille Lens Measurement
When replacing the Dock Frame assembly (item 36 on page 8) of the SoundDock
distance between the dock and the lens may fall out of specification. The measurement
between the dock and the lens is critical to the operation of the system. If the dock and the
lens are too close together, buzzing from the assembly and skipping from the iPod is possible.
To avoid these issues, ensure the distance between the dock and lens is 1.25mm +/- .09mm.
It may be necessary to disassemble and reassemble dock to align it correctly.
10. End Cap to Grill Measurement
Grille to Endcap 1.25
Variation 0.50
Left to Right Side 1.16
When an endcap (item 10 or 13 on page 8) is replaced on the SoundDock 10, the distance
between the grille and the endcap may fall out of the 1.25mm specification. During reassem-
bly, ensure the distance between the endcap and the grille is 1.25mm +/- 0.75mm. It may be
necessary to disassemble and reassemble the endcap to align it correctly.
± 0.75
21
Dock to Lens Gap 1.25
±
0.9
Variation 1.00
®