Checkpoint SLA Series Quick Setup
Hide thumbs Also See for SLA Series:

Advertisement

www.cppumps.com
WARNING:
Ensure that you are wearing proper PPE before performing any action.
This document applies to vertical and horizontal motor orientations.

Tool Requirements

Open-End Wrenches: Sizes required will depend on motor frame
Packing Gland Tool: T10010

Pump Mounting

1.
Unpack Series SLA pump assembly, and ensure all ordered components are
supplied. Fastener hardware not included. Motor sold separately.
QTY
1
1
2.
Place pump onto level mounting surface. The head should always be horizontal
relative to ground with the discharge check valve vertical facing up. See Figure 1.
3.
Secure pump to stable structure to avoid tipping, using four (4) holes on outer edge
of standard foot mount. See Figure 2.

Motor Attachment

4.
The Series SLA drive is designed to support up to an
85lbf (378N) motor.
5.
Install coupling hub with key to motor shaft and tighten
the set screw.
6.
Align the motor side coupling with the factory Series
SLA coupling hub, with the elastomer spider inserted.
7.
Align the motor flange with the Series SLA adapter
flange and secure by installing four (4) bolts (not
included) sized according to the motor frame.
8.
Connect motor to electrical service with overcurrent
protection and means to safely interrupt power,
following local rules and regulations.
DOC ID: CP/MAN-PRD-014
DESCRIPTION
SERIES SLA PUMP
SHAFT COUPLING HUB + SPIDER
QUICK SETUP
/
REV. 02
Series SLA
Figure 1
Figure 2
EFF. DATE: 07/08/2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLA Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Checkpoint SLA Series

  • Page 1 QUICK SETUP Series SLA www.cppumps.com WARNING: Ensure that you are wearing proper PPE before performing any action. This document applies to vertical and horizontal motor orientations. Tool Requirements Open-End Wrenches: Sizes required will depend on motor frame • Packing Gland Tool: T10010 •...
  • Page 2 QUICK SETUP Series SLA www.cppumps.com Pump Attachment Connect the suction line to the suction check valve. Connect the discharge line to the discharge check valve. Line size must be equal or greater than check valve connection. See Figure 3. Liquid level should be equal to or higher than pump inlet. 10.

Table of Contents