Page 1
Installation and configuration manual With Solis Hybrid Inverter Pytes Lithium Battery V series With Solis S5 Series Hybrid Inverter...
Page 2
BOM LIST Before installation, you should prepare following items. Definition CAN Port Pin for BMS is as follow. Item Remarks Quantity ◼ Conductor cross-section: UL10269- 1/0AWG-200mm- Amphonel 8.0mm Or TMR-190*25*18mm ◼ Cable diameters:14mm to 25mm Depends on the number ◼ Only copper cables may be used Power Cable of batteries and the ◼...
HOW TO INSTALL Communication Cable Power Cable Connection Connection Start up the System Parameters Setting System Monitoring and Checking on the Inverter CAUTION: If you want to get more inverter-related settings, please refer to the inverter user manual first.
1. Power Cable Connection Step.1 Open the front housing of the Victron Energy Inverter/Charger. Step.2 Connect the red cable and black cable to the inverter connector as shown in Pic 1.1 BATTERY+ BATTERY- Pic 1.1 Step.3 At the other end of the power cable, connect to the battery as shown Pic 1.2(Ensure that the battery power switch is off)...
Page 5
2. Communication Cable Connection CAN port definition Version Pin number of com. cable V Series Insert inverter end of the CAN cable into the controller at CAN. Insert battery end of the CAN cable into the battery at CAN. (Ensure the correct sequence of wires inside the CAN cable).
Page 6
Pic 2.1 3. Set the DIP Switch Set the DIP switch according to the version of 48100V you have, as shown in table below. Version ADD setting V Series 1. Start up the System Start up the battery. Firstly, press the power button on, next press the SW red ring button as shown in pic 3.1.
Page 7
2. Parameters Setting and Checking on the Inverter ※CAUTION: If you want more details about the batteries settings, please check the operating manual of inverter. Step1. Check the inverter main page on the screen. as shown in pic 5.1. Pic 5.1 Step2.
Page 8
Step3. Click the Advanced settings. Input Password number 0010, then enter the submenu to set parameters as shown in 5.3. There are many items in the submenu, please set them comply to the inverter manual for the details. The most important parameters setting is the Storage Energy Set, click into the item and set battery module to Pytes.
Page 9
Pic 5.4 Step5. Click the Advanced information and check Running Message as shown in 5.5. Pic 5.5 3. System Monitoring ※CAUTION: If you want more details about system monitoring, please download APP of inverters .