D. OPERATING SEQUENCE – WHIRLPOOL
SYSTEM
Refer to the chart at right for the proper operating
sequence.
1.
Turn on the whirlpool jets. Adjust each jet for
optimum air/water mixture.
2.
A built-in heater automatically maintains the water
temperature while whirlpool bathing.
3.
Press the BodySpa On/Off button to turn on the
Body Jets, and turn off the whirlpool.
4.
A built-in timer automatically stops the motor after
approximately 20 minutes of operation.
TE:
NO
The BodySpa and whirlpool functions will not
operate at the same time.

14. TROUBLESHOOTING PROCEDURES

A. FLEXJET INSTALLATION
NOTE: The Flexjet O-ring must be correctly positioned,
must be lubricated, and must be in good condition to
permit easy rotation and proper operation.
1.
Install the O-ring onto the first shoulder of the
Flexjet. Lubricate the O-ring with silicone lubricant
to prevent noisy operation of the Flexjet.
2.
Insert the Flexjet into the housing, and lightly push
and rotate the Flexjet until it snaps into position. Do
not force the Flexjet.
NOTE: When installed correctly, the Flexjet should turn
smoothly both clockwise and counterclockwise.
Kohler Co., Kohler, WI U.S.A.
TO
Turn on
whirlpool
massage and
the heater.
Decrease flow by
pressing
key;
increase flow by
pressing
key.
To add air and
Reduce
water to whirlpool
Air and
action, rotate
Water
the trim ring
counterclockwise.
To reduce air and
water, rotate it
clockwise.
Shut off whirlpool.
Restart whirlpool
after 20 minute
cycle is
complete.
Flexjet Housing
O-Ring (Must Be
Lubricated)
15
METHOD
OBSERVE
Up/
More
Down/
Less
Add Air
and
Water
First
Shoulder
Flexjet
114825-2-
AB

Advertisement