2-4. Notes on Removing/Installing the Imager Board (CD-1009 Flexible Board)

When the CD-1009 Flexible Board (Imager) is mounted to the lens, shift and tilt adjustment is made with Spacer Plates.
When removing the CD-1009 Flexible Board, pay attention to the following.
1.
When the lens is not replaced
Example: In the case of disassembly, cleaning, or replacement of the CD-1009 Flexible Board. (Imager)
Check and record the size of the built-in three Spacer Plates and store them so as not to lose them.
When assembling the CD-1009 Flexible Board, be sure to install the Spacer Plates to their original locations.
Note
Be careful not to lose the Spacer Plates.
If any Spacer Plate is lost or their previous positions are not sure, repeatedly take a photo and check that there is no local defocus.
Selecting appropriate Spacer Plates is needed.
2.
When the lens is replaced
Refer to "2-3. Notes on Replacing the Lens" for select Spacer Plates and install them to the new lens.
0.xx
Size
Sony CONFIDENTIAL