Download Print this page

Kin SKT 1000 User Manual page 14

Advertisement

Available languages

Available languages

Functions
Leakage
indicator
setting
Anti-block
setting
kinpumps.com
Setting
Function description
code
In F6 setting
F6
to set the leakage
In F7 setting
key"
to enable or disable the
F7
anti-block
Figures
It shall be fully checked whether electric pump is damaged during
transportation and storage prior to installation and
e.g. whether the cable or outgoing line and plug (if equipped)are
in good condition, and whether insulation resistance is more than
50MΩ
meet the requirement prior to use.
Prior to the use of electric
with water and drain the air before starting the water
When pumping well
3
minutes,
pump,
body. Tighten the vent cock and restart the water
repeat the operation
Electric pump shall be correctly installed with electrical
leakage protector, and reliably earthed at the earthing mark
of electric pump or cable, and the power socket connected
shall also be earthed reliably.
F6.0: Leakage indicator is disabled
F6.1: Leakage indicator is enabled
mode,
press "+/- key"
The leakage indicator is
indicator.
enabled by default.
F7.0: Anti-block indicator is
disabled
mode,
press "+/-
F7.1: Anti-block indicator is
enabled
function.
The anti-block indicator is
enabled by default.
Instructions for use
(megaohm),
or else technical support must be sought to
pump,
it is needed to fill the pump body
water,
if the water cannot be pumped for 2 to
it is needed to click the "On/Off " key to stop the
and then open the vent cock and add water into the pump
2~3
times until the pump pumps water out.
SKT 1000
Remarks
use,
pump.
pump,
and
14
GB

Advertisement

loading