Download Print this page

Xantech CSM1 Installation Instructions

Mrc44 current sense module

Advertisement

Quick Links

Figure 1 – CSM1 MRC44 Current Sense Module
Sense Input Connections (MRC44 Controller)
The sense input connection will typically be used to sense the power state of a source component
using the Xantech CSM1 Current Sense Module. Plug the 3.5mm miniplug from the CSM1 into
the appropriate sense jack. Be careful to match the source audio and video connection number
on the MRC44 to the sense jack number. The CSM1 plugs into an AC power source. The
component power cord plugs into the CSM1 (see Figure 2).
CSM1 Threshold Adjustments
a. First, make sure the 3.5mm mini-plug is plugged into the appropriate sense jack on the
MRC44 and that the MRC44 is powered ON. (The CSM1 gets low-voltage DC power from
the MRC44 – not from the AC line.)
b. Select the correct position of the RANGE slider switch – the HI position is for devices with a
high current draw when ON, the LO position is for devices with a low current draw when ON
(based upon the lowest current draw state of the component when ON).
c. Manually turn the component ON.
d. Using a small (1/8" wide) blade screwdriver, rotate the current control to the full CLOCKWISE
position (LO CURRENT).
e. Rotate the control COUNTER-CLOCKWISE (towards the HI CURRENT position) until the
Threshold Adjustment LED goes OFF.
f.
Turn the component OFF manually.
g. Rotate the control CLOCKWISE until the Threshold Adjustment just goes ON.
h. Set the control to a point midway between these two settings. This should be the correct
setting.
NOTE 1: If you have trouble with the threshold adjustment correctly detecting the ON and OFF
states of the component, try changing the RANGE slider to the opposite position and then try the
adjustment again.
NOTE 2: If the Threshold Adjustment LED does not go ON and OFF with the component power,
make minor adjustments to the threshold adjust until the LED is in proper sync.
NOTE 3: Program IR commands for the MRC44 Controller current sensing as described in the
MRC44 Installation Instructions, "PROGRAMMING SENSE CODES".
INSTALLATION INSTRUCTIONS
MODEL CSM1
MRC44 Current Sense Module
XANTECH CORPORATION
12950 Bradley Avenue, Sylmar CA 91342-3829
phone 818.362.0353 • fax 818.362.9506
www.xantech.com
Figure 2 – CSM1 Connections
Part No. 08901165 Rev A 03-29-2002

Advertisement