Summary of Contents for Elumen8 Evora CMY600 Profile

  • Page 1 Evora CMY600 Profile User Manual Order codes: ELUM703...
  • Page 2: Safety Advice

    Pack the unit securely (preferably in the Incorrect installation or use can cause serious damage original packing material), and return it to your Prolight to people and/or property. dealer for service. www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 3 To avoid damage to internal parts ie. optics, colour filters, gobos, prisms, frost filters, iris, shutters, motors, belts, wiring or LEDs never expose the front lens to direct sunlight, lighting fixtures or lasers even when the fixture is not in use. www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 4 Product overview & technical specifications Evora CMY600 Profile The Evora CMY600 Profile is a powerful tour-grade moving head which features a comprehensive array of effects. The impressive 600W LED provides an immense output, whilst the 4-blade, rotatable framing system, 9°- 46°...
  • Page 5: Technical Specifications

    Technical specifications 240mm 382mm 108mm 288mm 290mm 390mm 535mm www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 6 2 x omega clamps 03 - 5-Pin DMX input 07 - PowerCON TRUE1 input 10 - Wireless DMX Antenna & 1 x power cable 04 - 5-Pin DMX output 08 - PowerCON TRUE1 output 11 - Fans www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 7: Installation

    The installation should be checked annually by a qualified person. The eLumen8 Evora CMY600 Profile can be operated where the base of the fixture is horizontally orientated, this includes standing the fixture upright on a flat, level surface or hanging the fixture upside down.
  • Page 8 4. Mount the fixture onto your truss system via the clamps and tighten to ensure secure. 5. Pull the safety cable through the safety cable holes located on the metal base plate on the underside of the fixture and around the truss. www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 9 Pan/Tilt Lock Mechanism Pan mechanism lock and release every 45° UNLOCKED LOCKED Tilt mechanism lock and release every 45° LOCKED UNLOCKED www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 10: Rotating Gobo Replacement

    2) Use a Phillips head screwdriver to loosen the four 3) Remove the safety clips securing the casings to the screws on each side of the head casing. These are head chassis. twist lock screws and do not come free of the casing. www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 11 5) Unscrew the screws on either side of the framing module. Repeat this for the screws on either side of the gobo/colour wheel module. 6) Slide the zoom/focus mechanism upwards out of the way of the framing module. www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 12 9) Locate the gobo that will be replaced. Grip the edges of the gobo holder and carefully lift the holder until is raised from the surface of the gobo wheel. Pull the gobo holder towards you, away from the gobo wheel. www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 13 Install the new gobo and follow the previous steps in reverse order. Please note: the static gobo wheel is located underneath the rotating gobo wheel. Please follow instructions 9 & 10 to replace the static gobo(s). www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 14 The LCD control panel situated on the front of the fixture allows the user to access the menu system to adjust the fixtures settings. When the unit has been powered on the display will show “Software Update” followed by “eLumen8 Evora CMY600 Profile” and then “Ethernet Reset Please Wait...” followed by “Motor Reset Please Wait...”.
  • Page 15 Prism1Rot Prism2 Prism2Rot Focus Zoom BladeRot HeadTemp HeadFan1 HeadFan2 HeadFan3 HeadFan4 This message will appear if the sensor or fan has failed or the fixtures temperature is too hot. HeadFan5 GoboFan BaseTemp BaseFan Blower3 www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 16 W-DMX must be active for Link all devices and the link Tx/Rx Link with a transmitter must be suspended (Receive Reset) UnLink Unlink all devices Do not suspend link with transmitter Rx Reset Suspend link with transmitter www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 17 Iris Frost Prism 1 Prism 1 Rot Prism 2 Prism 2 Rot Animation Framing Rot Framing Rot Fine Blade 1A Blade 1B Blade 2A Blade 2B Blade 3A Blade 3B Blade 4A Blade 4B www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 18 DMX Fail DMX Fail Setting Programs Manual Standard Settings Stage Dim Mode Dimming Curve Speed Architectur Theatre 900Hz 1000Hz 1100Hz 1200Hz 1300Hz 1400Hz Frequency LED Refresh Rate Setting 1500Hz 2500Hz 4000Hz 5000Hz 10kHz 15Khz www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 19 Colour 5-6 Colour 6-7 Colour 7-0 Service Calibrate (PIN = 050) 000-255 Calibration Settings Gobo GoboRot. 1 GoboRot. 2 GoboRot. 3 GoboRot. 4 GoboRot. 5 GoboRot. 6 GoboRot. 7 FocusGoboR1 FocusGoboR2 FocusGoboR3 FocusGoboR4 FocusGoboR5 FocusGoboR6 www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 20 Blade 2A Blade 2B Blade 3A Blade 3B Blade 4A Blade 4B Auto Test Testing... Auto Test Pan & Tilt CMY/CTO Motor Reset Motor Reset Gobos/Colours/Prisms Zoom/Focus/Iris Blades USB Update USB Update Factory Factory Settings www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 21 Gobo Fan: xxxxRPM Base-1: xxxxRPM Model eLumen8 Evora CMY600 Hybrid Model Information RDM UID 0x09A5-xxxxxxxx RDM UID 1U: Vx.x.xx 2U: Vx.x.xx Firmware Software Version 3U: Vx.x.xx Error. Info NONE/Pan, Tilt... (See page 14) Current Fixture Errors www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 22 - 056-060 Colour 5/Colour 6 see page see page see page 061-065 Colour 6 066-070 Colour 6/Colour 7 071-075 Colour 7 076-080 Colour 7/Colour 8 081-085 Colour 8 086-090 Colour 8/Open 091-127 Open www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 23 Scroll anti-clockwise (fast-slow) – – 000-255 Cyan Fine Magenta Full 000-255 Magenta (0-100%) Effect Macros 000-170 Magenta (0-100%) 171-189 Magenta (100%-open) 190-221 Scroll clockwise (fast-slow) 222-223 Stop 224-255 Scroll anti-clockwise (fast-slow) – – 000-255 Magenta Fine www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 24 190-221 Scroll clockwise (fast-slow) 222-223 Stop 224-255 Scroll anti-clockwise (slow-fast) Rotating Gobo Wheel Index 000-127 Rotating Gobo Indexing 128-189 Scroll clockwise (fast-slow) 190-193 Stop 194-255 Scroll anti-clockwise (fast-slow) – 000-255 Rotating Gobo Indexing Fine www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 25 Strobe (slow-fast) 096-127 LED on 128-159 Pulse strobe (slow-fast) 160-191 LED on 192-223 Random strobe (slow-fast) 224-255 LED on 000-255 Dimmer (0-100%) – 000-255 Dimmer fine (16 bit) 000-255 Zoom (narrow-wide) – 000-255 Zoom fine www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 26 Framing Blade 1A (outward-inward) – – 000-255 Framing Blade 1A Fine 000-255 Framing Blade 1B (outward-inward) – – 000-255 Framing Blade 1B Fine 000-255 Framing Blade 2A (outward-inward) – – 000-255 Framing Blade 2A Fine www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 27 1100Hz (hold 3s) 113-120 1200Hz (hold 3s) 121-128 1300Hz (hold 3s) 129-136 1400Hz (hold 3s) 137-144 1500Hz (hold 3s) 145-152 2500Hz (hold 3s) 153-160 4000Hz (hold 3s) 161-168 5000Hz (hold 3s) 169-176 10kHz (hold 3s) www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 28 15kHz (hold 3s) 185-192 20kHz (hold 3s) 193-200 25kHz (hold 3s) (cont.) (cont.) (cont.) 201-208 Reset pan/tilt (hold 3s) 209-216 Reset head only (hold 3s) 217-224 Reset all motors (hold 3s) 225-255 No function www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 29 33% split 33% split Open 50% split 50% split Open 50% split 100% Open 100% 50% split Open 33% split 33% split Open 50% split 50% split 50% split Open 33% split 33% split Yellow www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 30 Ramp Effect Rise time (ms) Down time (ms) Rise time (ms) Down time (ms) Standard (default) Stage 1100 1540 1660 1180 1520 1860 1940 Architectural 1380 1730 2040 2120 Theatre 1580 1940 2230 2280 www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 31 Rotating gobos: Gobo size: 23mmØ Image size: 19mmØ Gobo thickness: 1.1mm (Max. thickness if replaced 1.1mm) Colour wheel: Static gobos: Gobo size: 23mmØ Image size: 19mmØ Gobo thickness: 1.1mm (Max. thickness if replaced 1.1mm) www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 32: Dmx Setup

    Please quote: 3-Pin: CABL10 – 2m CABL11 – 5m CABL12 – 10m 5-Pin: CABL185 – 2m CABL187 – 5m CABL188 – 10m Also remember that DMX cable must be daisy chained and cannot be split. www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 33 5-pin XLR (male) 3-pin XLR (female) Pin 1: GND (screen) Pin 1: GND (screen) Pin 2: Signal (-) Pin 2: Signal (-) Pin 3: Signal (+) Pin 3: Signal (+) Pin 4: N/C Pin 5: N/C www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 34 Please note: Caution should be used when power linking other fixtures to the Evora CMY600 Hybrid as the power consumption of other fixtures will vary. Fixtures fitted with lamps often require 2/3 times more current on startup, these may require their own power source. www.prolight.co.uk Evora CMY600 Profile User Manual...
  • Page 35: Weee Notice

    Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal. www.prolight.co.uk Evora CMY600 Profile User Manual...

This manual is also suitable for:

Elum703