Raytec URBAN-X Pro Installation Manual

Advertisement

Quick Links

URBAN-X Pro Installation Guide
• Lightweight and durable design
• Excellent efficacy >140lm/W
• The luminaires are Class 1 for

Safety Warnings

Eye Safety:
Caution – EN62471 Risk Group 2 Classification - Possible hazardous optical
radiation emitted from this product. May be harmful to eyes, do not stare at the
lamp. Hazard Distance is 2,750mm.
Warning: High Voltage product
All Electrical Installation work to be performed by a suitably qualified person in
line with the local regulations.
Risk of electric shock - isolate mains before removing cover.

Mechanical Installation:

Ensure unit is mounted securely to prevent risk of injury and the supply cord is installed as
per the instructions. Maximum mounting height 12M.

Box Contents

• URBAN-X Pro luminaire
• URBAN-X Pro pole mount arm
• 2 x Fixing grub screws
• 1 x Cable Tie
Raytec Global Tel: +44 (0) 1670 520055
Americas Tel: +1 613 270 9990
insulation
• Intelligent driver programs
• 5-year warranty
• The luminaires are suitable for use
outdoors and indoors
• 2 x M8 screw
• 2 x M8 washer
• 2 x M8 spring washer
www.rayteccctv.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the URBAN-X Pro and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Raytec URBAN-X Pro

  • Page 1 Box Contents • 2 x M8 screw • URBAN-X Pro luminaire • 2 x M8 washer • URBAN-X Pro pole mount arm • 2 x M8 spring washer • 2 x Fixing grub screws • 1 x Cable Tie Raytec Global Tel: +44 (0) 1670 520055 www.rayteccctv.com...
  • Page 2 - Make sure all wires are inside the product and none are trapped by the lid. - Tighten the two lid screws to 4Nm torque to ensure the environmental seal. • DALI connection (when used): The additional cores should be stripped to 8.5mm – 9.5mm and suitably terminated. - Connect the two wires directly to the driver terminals labelled DA(BL) Blue. The connection is non-polarity sensitive. www.rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...
  • Page 3 ID1 - Soft Start: 100% output for duration of night (5 second soft start). ID2 - Timer Dimming: 100% power (5 second soft start) for 5 hours from power up, then 50% power until the next cycle. *ID3 - Active Dimming 50% *ID4 - Active Dimming 25%: 100% output (5 second soft start) from power up, then dims to either 50% (ID3) or 25% (ID4) power, around the midpoint of the night and up to a maximum of 6 hours after, then back to 100% if it’s still dark. This program would typically require the use of an inbuilt or remote photocell to monitor the hours of darkness. Raytec Global Tel: +44 (0) 1670 520055 www.rayteccctv.com Americas Tel: +1 613 270 9990...
  • Page 4 Urban-X PRO Troubleshoot Ensure all tests are undertaken by a qualified, trained engineer. Ensure safe working practices are followed at all times. • Check mains input • Check all mains wiring connections are correct • Check photocell is working (if fitted) • Check Driver Program • Check luminaire physical alignment • If DALI controlled check DALI communications and connections • Call Raytec for further assistance *Model shown without photocell fitted* www.rayteccctv.com Raytec Global Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990...

Table of Contents