DINKY LINK™ INFRARED RECEIVERS
These small IR receivers have been designed for mounting in very small spaces. They may be mounted
under shelf edges, cabinet ledges, in wall speakers, etc. - anywhere an inconspicuous appearance is
desired. The high sensitivity of these receivers allows placement behind speakers grilles and still receive
IR commands up to 20 feet away. If longer range is necessary, a 3/8-inch hole must be drilled in the grille
to allow unobstructed entry of the IR signal. The model versions covered by these instructions are as
follows:
480B-00
Standard version, with black case. Has a 7 foot, three-conductor ribbon cable with stripped and
tinned ends.
480W-00
Same as the 480B-00 except with white case.
480B-30
Quick connect version of the 480B-00. 7-foot cable with 3.5 mm stereo mini plug for direct plug-
in to Xantech Connecting Blocks, such as the CB12, CB20, 789-44, 791-44, etc.
480W-30
Same as 480B-30 except with white case.
Each version in the 480 series has the same features and specifications as follows:
FEATURES
• Very small package, only 7/16" x 5/16" x 2-1/8".
• Works in normal 3-wire mode or 2-wire phantom power mode.
• Phantom mode requires 792-10 power module.
• System testing red talk-back LED.
• Includes 3-Terminal Block for easy extension of 7 foot ribbon cable.
• 20 units may be powered by one 781RG power supply.
• SUN480 Sunscreen filters available separately. Order these to help with sunlight and stray IR problems.
They fit easily over the photodiode opening.
SPECIFICATIONS
• Infrared carrier frequency bandwidth: 30 - 100 kHz.
• Reception range: up to 30 feet, depending on local conditions.
• Nominal reception angle: 55 degrees off axis.
• Cable requirements: see "INSTALLATION" on following page (unshielded OK).
• Maximum transmission length: One mile using 18 gauge wire.
• Maximum current output: 100 mA.
• Drives IR emitters through Xantech Connecting Blocks, Controllers, etc.
• Dimensions: 7/16" x 5/16" x 2-1/8".
• Power requirements: 12 volts DC @ 10 mA.

INSTALLATION INSTRUCTIONS

480 SERIES
1

Advertisement

loading

Summary of Contents for Xantech Dinky Link 480B-30

  • Page 1: Installation Instructions

    Same as the 480B-00 except with white case. 480B-30 Quick connect version of the 480B-00. 7-foot cable with 3.5 mm stereo mini plug for direct plug- in to Xantech Connecting Blocks, such as the CB12, CB20, 789-44, 791-44, etc. 480W-30 Same as 480B-30 except with white case.
  • Page 2 Model 480-30 Series. These units, equipped with a 7-foot cable and 3.5 mm stereo type mini plug, are plugged directly into the "IR RCVR" or "AUX" jack on Xantech Connecting Blocks, such as the CB12, CB20, 789-44, 791-44, etc. The 480-30 should be used in installations where the connecting block is within reach...
  • Page 3 POWER MODULE 1 (ON) +12V +12V 0 (OFF) 1 2 3 4 5 6 7 8 9 1 0 1 2 3 4 5 6 7 8 9 10 XANTECH CORPORATION 2-Conductor Inter-room Cable (usually coax) MAIN ROOM  790-00...