Functional Safety K*D0-RSH-1.1D.(F)*, HiC5861(Y1)
Product Description
2
Product Description
2.1
Function
General
This signal conditioner provides galvanic isolation between field circuits and control circuits.
The de-energized to safe (DTS) function is permitted for SIL 3 and PL e applications.
For testing of the relays, test terminals can be used. The test mode will be indicated by a LED.
KFD0-RSH-1.1D.F1
The device is supplied with a replaceable fuse of 2.5 AF.
The device is a relay module that is suitable for safely switching applications of a load circuit.
The device isolates load circuits up to 230 V AC and the 24 V DC control circuit.
The device is mounted on a 35 mm DIN mounting rail according to EN 60715.
KCD0-RSH-1.1D.1
The device is supplied with an internal fuse of 4 AT.
The device is a relay module that is suitable for safely switching applications of a load circuit.
The device isolates load circuits up to 230 V AC and the 24 V DC control circuit.
The device is mounted on a 35 mm DIN mounting rail according to EN 60715.
KCD0-RSH-1.1D.4
The device is supplied with an internal fuse of 5 AT.
The device is a relay module that is suitable for safely switching applications of a load circuit.
The device isolates load circuits up to 115 V and the 24 V control circuit.
The device is mounted on a 35 mm DIN mounting rail according to EN 60715.
HiC5861
The device is supplied with an internal fuse of 1.5 AT.
The device is a relay module that is suitable for safely switching applications of a load circuit.
The device isolates load circuits up to 30 V and the 24 V control circuit.
This device mounts on a HiC termination board.
HiC5861Y1
The device is supplied with an internal fuse of 3.15 AT.
The device is a relay module that is suitable for safely switching applications of a load circuit.
The device isolates load circuits up to 30 V and the 24 V control circuit.
This device mounts on a HiC termination board.