Summary of Contents for Hanskamp MultiFill 003-561-005
Page 1
Liquid dosing system Vloeistofdoseersysteem Flüssigkeitsdosiersystem Système de dosage pour liquide Installation and Operating Instructions Article number: 010-106-000 Date: December 2023 Doetinchem, Version 2.8 - Adjusted instruction manual The Netherlands According to Annex IIA of the Machinery Directive 2006/42/EC for completed machinery www.hanskamp.com...
Page 2
Please consult your milking equipment dealer if you do not understand the information in this manual, or if you need additional information. All information in this manual has been compiled with care. Hanskamp shall not be liable for errors or faults in this manual. The recommendations are meant to serve as guidelines.
Page 3
The information in this manual is intended for dairy farmers and technicians. • Dairy farmers can use the information to test and adjust the MultiFill. • Technicians can use the information to install and set up the MultiFill. 3 - 20 Hanskamp AgroTech BV (The Netherlands) www.hanskamp.com...
• Only use original spare parts, and make sure that they are fitted by authorised technicians. 4 - 20 Hanskamp AgroTech BV (The Netherlands) www.hanskamp.com...
Page 5
Before connecting the MultiFill to the power supply, make sure that all parts are properly tightened and that all cables and mountings are in good condition. • If you have any other questions, please contact your milking technology dealer. 5 - 20 Hanskamp AgroTech BV (The Netherlands) www.hanskamp.com...
Page 6
This chapter lists the general safety messages. Specific safety messages, where potential hazards may arise if the procedures or instructions are not followed, are included in the appropriate sections of this manual. 6 - 20 Hanskamp AgroTech BV (The Netherlands) www.hanskamp.com...
Installation instruction General description The Hanskamp MultiFill dosing system is a refill system for automatically filling the MultiDos container. This installation instruction will guide you through the installation of the MultiFill system (fig. 1). Read this instruction carefully and follow the safety instructions.
Page 8
Caution! Drill a small hole into the top of the storage drum for ventilation purposes. Caution! Fill the container completely by hand the first time. Let the MultiFill refill only the last millilitres. 8 - 20 Hanskamp AgroTech BV (The Netherlands) www.hanskamp.com...
Page 9
Carefully open the cover of the motor housing. Push the cable of the power supply through the centre grommet. Strip the insulation at the ends of the wires. Distance between tube and plate: ± 8 mm 9 - 20 Hanskamp AgroTech BV (The Netherlands) www.hanskamp.com...
Page 10
Magnet LED (orange) On = magnet sensor detects magnet (not used) Pressure signal available (blue) On = pressure higher than 2 bar Motor LED (red) On = signal on motor output 10 - 20 Hanskamp AgroTech BV (The Netherlands) www.hanskamp.com...
Page 11
1x pressure hose = 50 m PVC hose Ø14x10 art. no. 001-007-001 Please note! Hanskamp can only guarantee proper operation if the length of the suction hose is 2 meters or less. Take the suction hose and push it, from below, onto the right-hand feedthrough coupling (art.
Page 12
Please note! To prevent loss of liquid in case of leakage, the MultiFill stops auto- matically after 6 hours of continuous rotation and emits a sound signal. To restart the MultiFill, briefly disconnect the power supply and then reconnect it, using the power adapter. 12 - 20 Hanskamp AgroTech BV (The Netherlands) www.hanskamp.com...
Page 13
6). A suitable repair kit can be obtained from Hanskamp. Also check the rollers and bearings for wear. For these too, Hanskamp can supply repair kits. Caution! Always disconnect the pump motor from the power supply before carrying out maintenance and/or disassembly.
Page 14
If the MultiFill is not connected and the prescribed safety instructions are not used, this Declaration of Conformity is not applicable and no rights can be derived from this decla- ration. Doetinchem, the Netherlands, 05-12-2023 H.J. Hanskamp 14 - 20 Hanskamp AgroTech BV (The Netherlands) www.hanskamp.com...
Suction height 2 meters Pressure height 4 meters Max. length pressure hose 50 meters Control range Regulates between 0.8 and 2 bar Certificate NEN 3140 Power cord 3 meter cord with plug 15 - 20 Hanskamp AgroTech BV (The Netherlands) www.hanskamp.com...
50 m 24V DC, 1500 mA 002-260-000 Float valve set MultiFill 011-234-000 Housing for sensor PCB, grey 082-342-002 Air tube PU/2 cm 4x2, transparent 082-342-029 Air tube PU/29 cm 4x2, transparent 17 - 20 Hanskamp AgroTech BV (The Netherlands) www.hanskamp.com...
Frictional resistance due to deficient maintenance or wear on the rollers and guides; Twisted, kinked or excess length of the HanskampQualityTube installed in the Mul- tiFill; Wall thickness and thickness variation. 18 - 20 Hanskamp AgroTech BV (The Netherlands) www.hanskamp.com...
Page 19
No part of this publication may be reproduced or made public without the prior written consent of Hanskamp Ag roTech BV. Although this publication has been compiled with the greatest care, Hanskamp AgroTech BV is not liable for any damage that may arise d ue to any errors or omis- sions it might contain.
Page 20
Dosing system - Dosiersystem - Système de dosage - Doseersysteem Hanskamp AgroTech BV Broekstraat 17 7009 ZB Doetinchem Also take a look at: The Netherlands Tel: +31 (0)314 - 393 797 Fax: +31 (0)314 - 393 826 www.hanskamp.com 20 - 20 Hanskamp AgroTech BV (The Netherlands) www.hanskamp.com...